3. INSTALLATION

3.1 HOW TO INSTALL THE UNIT

For existing sleeve, you should measure the wall sleeve
dimensions.
You can install the new air conditioner according to these
installation instructions to achieve the best performence. All
wall sleeves used to mount the new air conditioner must be in
good structural condition and have the rear grille that securely
attaches to the sleeve or the flange of the sleeve to secure the
new air conditioner.

• To avoid vibration and noise, make sure the unit is installed

securely and firmly.

A. BEFORE ATTACHING THE FRONT

GRILLE TO THE SLEEVE, IF YOU WANT
TO PULL OUT THE FILTER UPWARD;

1. There should be no obstacle, like a fence, within 20" which

might restrict heat radiation from the condenser.

B. IF YOU WANT TO PULL OUT THE FILTER

DOWNWARD;

The grille is already designed for that way.
1. Install the unit a little obliquely outward not to leak the

condensed water into the room (about 1/2" or 1/4" bubble
with level).

2. Install the unit with its bottom portion 30~60" above the floor

level.

3. The power cord must be connected to an independent

circuit. The green wire must be grounded.

406mm

(16")

406mm

(16")

1,066mm(42")

1066mm

(42")

318mm

(12

1

/

2

")

318mm

(12

1

/

2

")

505mm

(20")

Over 20"

HEAT

RADIATION

WALL

WALL

INSULATION

SLEEVE

INTAKE

AIR

COOLED

AIR

Level

1/4" Bubble

1/4" Bubble

of the level

;

;

;

y

y

y

• There are sharp edges that can cause serious cuts.
• When lifting the air conditioner, it is HEAVY.

Use 2 peoples to lift.

CAUTION

Dimension of air conditioner

Dimension of sleeve assembly (optional)