OPERATING INSTRUCTIONS

Engine with fixed throttle:

Move the engine stop switch to the ON

position.
For more details see engine manual.

Step 9

Pull the starter handle.

If the engine fails to start after 3 pulls,

squeeze the trigger gun to release

pressure, and repeat step.

After the engine warms up enough to run

smoothly, move choke rod to OPEN position

and throttle to FAST position.

Important!
Do not run the engine with a high or low oil

level as this can cause engine damage.
If you have further questions regarding the

engine, please refer to the engine’s

operating manual included with the unit.

Step 1

Check oil level on engine before starting the

unit. Oil level should always be between the

“FULL” and “ADD” marks on the dipstick.

Be sure the machine is level when checking

the oil level. (Refer to the engine’s operating

manual for seasonal grades.).
We recommend that the oil be changed after

the first 2 hours of use, then once every 25

hours.
Step 2

Fill gas tank with unleaded gasoline.

Do not use leaded gasoline.
Step 3
Connect the high pressure hose to the unit’s

high pressure outlet.
Step 4

Connect garden hose to unit’s water inlet.
Step 5

Connect garden hose to the cold water

source and turn water on completely.

Do not use hot water.
Step 6

Trigger the gun to eliminate trapped air, wait

for a steady flow of water to emerge from

the spray nozzle.
Step 7

Pull the choke rod to the CLOSED position

Starting a Warm Engine:

If the engine has run out of fuel, pull the choke

rod to the CLOSED position after refueling.

If the engine has not run out of fuel, leave

the choke rod in the OPEN position.
Step 8

Engine with manual throttle:

Slide the throttle lever away from the SLOW

position, about 1/3 of the way toward the

FAST position.

MAINTENANCE INTERVALS
FOR PUMP

We recommend that the oil be changed

after the first 100 hours of use, then once

every 500 hours.

Recommended oil for pump

Use multi-grade 4-stroke motor oil that

meets or exceeds the requirement for API

service classification SH, SJ, or equivalent.

Use oul SAE-class 15W-40.

Oil Change for pump

Drain the pump oil when the pump is warm.

Warm oil drains quickly and completely.
1. Place a suitable container below the

pump to catch the used oil.

2. Remove the oil fill cap, the oil drain plug

and washer.

3. Allow the used oil to drain completely,

then reinstall the drain plug and washer.

Tighten the drain plug securely.

Please dispose of used oil in a manner

that is compatible with the environment.

We suggest you take used oil in a sealed

container to your local recycling center.

Do not throw it in a trash or pour it on the

ground or down a drain.

4. With the pump in a level position, fill in

0.190 liters (7.0 oz) of recommended oil.

Do not overfill.

Notice: Running the pump with a low oil

level can cause pump damage.

5. Reinstall the oil fill cap securely.