You can rectify minor faults yourself with
the help of the following overview.
If in doubt, please consult the authorized
customer service.

ƽ

Danger

Turn off the appliance and remove the
mains plug prior to any care and mainte-
nance work.
Repair works may only be performed by the
authorized customer service.

Pull on the lever of the trigger gun; the
device will switch on.

Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the mains supply.

Check the mains connection cable for
damages.

Check setting at the spray lance.

Remove air from appliance before oper-
ation.
Switch on the appliance without con-
nection the HP hose (max. 2 minutes)
and run it until the water discharging
from the HP outlet is free of bubbles.
Switch off appliance and reconnect HP
hose.

Check the water supply.

Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.

Cause: Voltage reduction due to weak
mains supply or when using an extension
cable
.

When switching on, first pull the lever of
the trigger gun and then switch the ap-
pliance switch to "I/ON".

Clean high-pressure nozzle: Remove
dirt and debris from the nozzle bore, us-
ing a needle and rinse through with wa-
ter from the front.

Check water flow quantity.

Slight leakage from the appliance pump
is normal. If the leakage increases con-
tact the authorized customer service.

Use spray lance with pressure regula-
tion (Vario Power).
Turn the spray lance to "Mix" position.

Check the settings at the dosage regu-
lator for detergent.

Check the detergent suction hose for
kinks.

Subject to technical modifications!

Troubleshooting

Appliance is not running

Pressure does not build up in the appliance

Appliance does not start, motor hums

Strong pressure fluctuations

Appliance is leaking

No detergent infeed

Technical specifications

Power connection
Voltage
1~50 Hz

240

V

Connected load

2,1

kW

Mains fuse (slow-blow)

10

A

Protective class

I

Protection class

IP X5

Water connection
Max. feed temperature

40

°C

Min. feed volume

10

I/min

Max. feed pressure

0,8

MPa

Max. Suction height

0,5

m

Performance data
Working pressure

12,5 MPa

Max. permissible pressure

14

MPa

2030 PSI

Water flow rate

7,5

I/min

Detergent flow rate

0 - 0,3 I/min