7
Ductwork Installation
5.
Use aluminum or steel pipe to connect the
6” round plastic exhaust on the hood to
the ductwork above. Use duct tape to
make all joints secure and air tight. Refer
to Figure 4.
6.
To convert ductwork to 7” round, attached
7” round adapter (provided) to the 6”
round plastic exhaust.
Wiring to Power Supply
SAFETY W A RNIN G
RISK OF ELECTRICAL SHOCK. THIS
RANGE HOOD MUST BE PROPERLY
GROUNDED. MAKE SURE THIS IS DONE
BY
SPECIALIZED
ELECTRICIAN
IN
ACCORDANCE WITH ALL APPLICABLE
NATIONAL AND LOCAL ELECTRICAL
CODES. BEFORE CONNECTING WIRES,
SWITCH POWER OFF AT SERVICE PANEL
AND LOCK SERVICE PANEL TO PREVENT
POWER FROM BEING SWITCHED ON
ACCIDENTALLY.
7.
Connect the electrical wires.
-
Connect three wires (black, white and
green) to house wires and cap with wire
connectors. Connect according to color:
black to black, white to white, and green
to green as shown on Figure 5.
-
If necessary to hide the electrical wire
connections, push wires back into the
wiring box. Access the wire connections
underneath the hood. Make sure wires
do not slip between motor or any
moving parts to prevent any damage.
Accessories
8.
Attach oil tunnel. Refer to Figure 6.
9.
Refer to Figure 7. Slide the baffle filter
into the hood. Push the baffle filter
upward. Slide forward. Pull
downward. Fit into place.
10. For bottom casing, repeat above steps.
Refer to page 15.
Final Assembly
11. Turn power ON in control panel. Check
all lights and fan operation.
12. Make sure to leave this manual for the
homeowner.