beautypg.com

Servicer’s tech. information, 5b. regeneration cycle times – Kenmore 625.3483500 User Manual

Page 23

background image

SERVICER’S TECH. INFORMATION

SECTION 5

23

5B.

REGENERATION CYCLE TIMES

See regeneration table on page 20, and specifications, page 21.

CYCLE FLOW RATES (GALLONS PER MINUTE)

FILL (flow to salt storage tank)

0.1 (1.1 liters)

BRINING

.16 (.6 liters)

BRINE RINSE

(flow to drain)

.11 (.4 liters)

BACKWASH

(flow to drain)

1.8 (6.8 liters)

FAST RINSE

1.8 (6.8 liters)

TO SET DOUBLE BACKWASH

(

Softener has a backwash and fast rinse cycle before brining, and after brining, which is

beneficial on some kinds of iron bearing water

):

USE BUTTONS

(SET/CLEAR), and

(PRESENT TIME AND DAY)

1

.

Press and hold

entire display comes on.

. . . . . . . . . . . . . . .

" Press

to display 3 dashes

" Press

to display dbl

" Press

to display 18:88

2

.

Press

to return present time.

REPEAT ABOVE STEPS TO CANCEL DOUBLE BACKWASH.

CYCLE SEQUENCE WITH DOUBLE BACKWASH

:

1. Fill 2. Backwash 3. Fast Rinse 4. Brining/Brine Rinse 5. BackĆ

wash 6. Fast Rinse Ċ Return to Service

OTHER RECHARGE CYCLE TIME ADJUSTMENTS

Cycle times in specifications are factory settings. Do the following to check for correct cycle times.

NOTE: Removing from electrical power (varies from 6 to 15

hours) resets timer to factory programming.

DISPLAY MUST SHOW TIME AND DA

Y

1

.

Press and hold

entire display

comes on.

2

.

Press

2:08 shows; meaning

#2 cycle (brining & br. rinse) and

80 minutes (8 x 10).

a

.

If 2:08 does show, go to step 3.

b

.

If other than 2:08 (2:00 to 2:15),

press

until 2:08 shows.

3

.

Press

3:12 shows, meaning

#3 cycle (backwash) and 12 minutes.

a

.

If 3:12 does show, go to step 4.

b

.

If other than 3:12 (3:00 to 3:30),

press

until 3:12 shows.

NOTE: Instead of programming a double backwash, a

longer single backwash is beneficial on some types of iron

water.

4

.

Press

4:04 shows; meaning

#4 cycle (fast rinse) and 4 minutes.

a

.

If 4:04 does show, go to step 5.

b

.

If other than 4:04 (4:00 to 4:30),

press

until 4:04 shows.

5

.

Press

18:88 shows.

6

.

Press

to return to present time and day.

TO SET MINUTE — LENGTH OF FILL CYCLE

(factory setting, 16 minutes

)

USE BUTTONS

(RECHARGE TIME),

(SET/CLEAR), and

(PRESENT TIME AND DAY)

1

.

Press and hold

until FILL shows, then 16 (factory setting).

" Press

to set the desired fill minutes

(from regeneration table).

2

.

Press

to return present time and day.

This manual is related to the following products: