Part

Dimensions

Case/

Number

I 2 of 5

Pack Quantity

(w x d x h inches)

Weight

Skid

21008905

100-47871-08905-2

Cut Case (4 units)

8 x 9.5 x 11.5

3.5lb

72

21008908

100-47871-08908-3

Bulk Pack (6 units)

6.4 x 12.2 x 6.8

3.9lb

105

2.75”

Technical Specifications

Power Source:

3 AA Batteries

Sensor:

Electrochemical

Audio Alarm:

85dB at 10ft

Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C)
Humidity Range:

5%-95% relative humidity (RH)

Size:

4.5”L x 2.75”H x 1.5” D

Weight:

.5lb

Wiring:

None

Interconnects:

No

Warranty:

5 year limited

Battery Operated

Carbon Monoxide Alarm

Part Number 21008905

Model 9CO5-LP

Architectural and Engineering

Specifications

The carbon monoxide alarm shall be Kidde Unit Number KN-COB-B
(part number 9CO5) or approved equal. It shall be powered by three
(3) AA batteries (included). The unit shall have a snap open cover
that allows immediate access to batteries. The temperature operating
range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humid-
ity operating range shall be 5% - 95% relative humidity.

The CO sensor shall be of a fuel cell design and shall meet the

sensitivity requirements of Underwriters Laboratories UL2034 Single
and Multiple Station Carbon Monoxide Alarms.

The alarm can be installed on the surface of any wall or ceiling

following the UL/NFPA/Manufacturer’s recommended placement
guidelines. The alarm shall include a battery lockout system that
deters closure of battery door without using three batteries.

The alarm shall include a test button that will electronically simu-

late the presence of CO and cause the unit to go into alarm. This
sequence tests the unit’s electronics to ensure proper operation.

Per UL 2034 requirements, the CO sensor will not alarm to levels

of CO below 30 ppm and will alarm in the following time range when
exposed to the corresponding levels of CO.

70 ppm CO Concentration 60 – 240 minutes

150 ppm CO Concentration 10 – 50 minutes

400 ppm CO Concentration 4 – 15 minutes

The unit shall incorporate 2 LED’s. A green LED will flash once

every 30 seconds to indicate the alarm is operating properly when
power is present. A red LED will pulse to to indicate carbon monoxide
has been detected until the device is reset or CO is eliminated.

The alarm shall include a piezoelectric horn that is rated at 85

decibels at 10 feet. When the unit detects carbon monoxide, the
alarm pattern will be four (4) short beeps – followed by five (5)
seconds of silence – followed by four (4) short beeps with a
corresponding red LED flash.

It shall also include a 5-year manufacturer’s limited warranty.

**Not for sale by individual unit

Ordering Information

Clamshell UPC: 0-47871-08905-5 Bulk UPC: 0-47871-08908-5

1016 Corporate Park Drive
Mebane NC 27302
1-800-880-6788
www.Kidde.com

KL-9CO5-LP sheet

rev. 03-2011

Distributed by:

4.5”