The Hush

®

feature can be used repeatedly until the air

has been cleared of the condition causing the alarm.

While the unit is in Hush

®

mode, pushing the

Test/Reset/Hush

®

button on the alarm will also end the

Hush

®

period.

NOTE: Dense smoke will override the Hush

®

control

feature and sound a continuous alarm.

CAUTION: Before using the alarm Hush

®

feature,

identify the source of the smoke and be certain a safe
condition exists.

Reset Feature

If the the Smoke/CO Alarm is sounding a CO alarm,
pressing the Test/Reset/Hush

®

button will silence the

alarm. If the CO condition that caused the alert
continues, the alarm will reactivate. Reactivation times
depend on the amount of CO present (see Page 24).

Peak Level Memory

If the CO sensor has detected a CO level of 100 PPM
or higher since last reset, it will be recorded by the
Peak Level Memory function. To access the Peak Level
Memory, press the Test/Reset/Hush

®

button. If a

reading of 100 PPM or higher has been recorded, the
unit will announce, "Caution! Attention!" If you’ve
been away from home, this feature allows you to
check if there was a CO reading of 100 or higher
during your absence. Pushing the Test/Reset/Hush

®

button resets the memory. The memory is also reset
when the unit loses power.

Interconnect Feature

IMPORTANT: This unit is only approved to
interconnect with the Kidde line of products. It is not
approved to interconnect with any other manufacturer's
products.

• When compatible smoke alarms (1235CA, 1275CA,

1285CA, PE120CA, PI2000CA) and heat alarms
(HD135F) are interconnected to this alarm, they will
only respond to a smoke related event.

• When mixing compatible models with battery

backup (1275CA, 1285CA, PE120CA, PI2000CA,
HD135F, KN-COSM-IBCA) with models without
battery backup (1235CA, KN-COSM-ICA), be advised
that the models without battery backup will not
respond during an AC power failure.

For more information about compatible interconnect
units and their functionality in an interconnect system,
visit our web site at: www.kidde.ca

Hush

®

Control Feature

The Hush

®

feature has the capability of temporarily

desensitizing the smoke alarm circuit for about
10 minutes. This feature is to be used only when a
known alarm condition, such as smoke from cooking,
activates the alarm. You can put the Smoke/CO Alarm
in Hush

®

mode by pushing the Test/Reset/Hush

®

button. If the smoke is not too dense, the alarm will
silence immediately, verbally announce, "Hush

®

mode

on! Mode Hush

®

activé!"

, and the green LED will flash

every 2 seconds for approximately 10 minutes. This
indicates that the smoke alarm is in a temporarily
desensitized condition. The alarm will automatically
reset after approximately 10 minutes. When the unit
returns to normal operation after being in Hush

®

mode, it will verbally announce, "Hush

®

mode

cancelled! Mode Hush

®

annulé!"

and sound the alarm

if smoke is still present.

O p e r a t i o n

O p e r a t i o n

17

16

810-1692_RevD_119-133_MAN_ENG 10/7/03 4:41 PM Page 16