6. Troubleshooting

Danger! Before any repair work is undertaken, switch the cleaner off and pull out the power plug.
Have electrical components checked and repaired only be authorised Customer Service personnel.
For faults which are not identified in this chapter, or when in doubt or when expressly instructed to do
so, consult authorised Customer Service personnel.

Cleaner does not work

Check mains voltage.
Check connecting cable for damage.
If the motor has overheated, let the cleaner cool

down. Then switch it on again.

Consult Customer Service if there is an

electrical fault.

Cleaner does not come up to pressure

Set nozzle (22) to “high pressure”.
Clean nozzle or replace with new one.
Clean strainer at the water connection (15).
Evacuate air from the cleaner.
Check water inlet volume (see Technical

Specifications).

Check all supply lines to the pump for leaks or

obstructions.

Seek the help of Customer Service

if necessary.

Pump is leaky

Three drops per minute are allowable and can

appear on the underside of the cleaner. Seek
the help of Customer Service if leaks are more
serious.

Pump makes a knocking noise

Check all supply lines as well as the detergent

system for leaks.

Evacuate air from the cleaner.
Seek the help of Customer Service

if necessary.

Detergent is not being drawn in

Set nozzle (22) to “low pressure”.
Check detergent suction hose (11) with filter for

leaks or obstructions and clean it if necessary.

Clean/renew non-return valve in detergent

suction-hose (11) connection.

Open detergent metering valve (8) or

check it for leaks/remove obstruction.
Also clean venting orifice in the cap.

Tip the cleaner backwards over the wheels.

Empty the detergent reservoir (10) and rinse
it out.

Seek the help of Customer Service

if necessary.

7. Spare parts

You will find a list of spare parts at the end of
these operating instructions.