Architectural and Engineering
Specifications
The carbon monoxide alarm shall be Kidde Unit Number KN-COP-
DP (part number 900-0056) or approved equal. It shall be powered
by a 120VAC, 60 Hz source. The temperature operating range shall
be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity opera-
tion range shall be 5% - 95% relative humidity.
The CO sensor shall be of a fuel cell design and shall meet the
sensitivity requirements of Underwriters Laboratories UL 2034 Single
Station Carbon Monoxide Detectors. The unit shall provide accura-
cy of +/-20% + 15 parts per million (ppm) when reading CO con-
centration levels.
The alarm shall include an attached plug that can be installed
in any outlet following the UL/NFPA/Manufacturer’s recommended
guidelines. The plug shall be capable of being rotated so the alarm
remains vertical independent of whether the electrical socket is
mounted vertically or horizontally.
The unit shall incorporate a digital display that meets the sensi-
tivity requirements of UL 2034. The display will identify the levels of
CO in parts per million (ppm) once that level reaches 30ppm (i.e.:
“abnormal” levels). The display will have a red dot in the lower
right corner that will blink to indicate the normal operation.
The alarm shall include a test button that will electronically
simulate the presence of CO and cause the unit to go into alarm.
This sequence tests the unit’s electronics to ensure proper operation.
The CO sensor will not alarm to levels of CO below 30 ppm
and will alarm in the following time range when exposed to the
corresponding level of CO.
The alarm shall include a piezoelectric horn that is rated at 85
decibels at 10 feet. When the unit detects carbon monoxide, the
alarm pattern will be four (4) short beeps – followed by five (5)
seconds of silence – followed by four (4) short beeps. A number
reading will appear on the digital display identifying the CO
concentration (in ppm).
The unit shall include a peak level memory feature that will
store the peak CO level sensed since the unit was last reset. The
peak CO level stored in the unit’s memory shall be displayed (in
ppm) on the digital display by pressing the appropriate button
on the unit. The memory shall also be capable of being reset.
The unit shall be listed to UL 2034. It shall also include a 5-year
manufacturer’s limited warranty.
Technical Specifications
Part Number:
900-0056
Unit Number:
KN-COP-DP
UPC Number:
7-84608-00560-1
Power Source:
120VAC
Sensor:
Electrochemical
Audio Alarm:
85dB at 10ft
Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C)
Humidity Range:
Up to 95% relative humidity (RH)
Size:
5.65”L x 3.25”W x 1.9”H
Weight:
1lb
Interconnects:
No
Wiring:
Plug-In
LED:
Displays CO concentration in PPM
Warranty:
5 year limited
*Based on accuracy claims of major manufacturers
UNIT
MASTER PACK
CUT CASE
POWER TOWER
1
PDQ
2
4
12
36
Ordering Information
Clam Shell UPC: 7-84908-00560-1
Part
Dimensions
Case/
Layers/
Skid
Number
I 2 of 5
Pack Quantity
(w x d x h inches)
Weight
Skid
Skid
Weight
900-0056**
N/A
Individual
7 x 2.5 x 10.75
1lb
N/A
N/A
N/A
900-0056-02
107 84908 00560 8
PDQ (2 units)
7.75 x 6 x 11.75
2lbs
105
3
210lbs
900-0056-07
207 84908 00560 5
Master Pack (4 units)
7.75 x 11.5 x 12
4lbs
80
4
320lbs
900-0056-012
307 84908 00560 2
Cut Case (12 units)
15 x 18 x 12
12lbs
18
3
216lbs
900-0056-036
407 84908 00560 9
Power Tower (36 units)
20 x 24 x 50 (incl. pallet)
36lbs
3
3
108lbs
**Not for sale by individual unit
3.25"
1.9"
5.65"
Distributed by: