Warning, Electrical requirements – KITCHENAID KBGS274SSS0 User Manual

Page 6

background image

6

Grill size

A

B

27” (68.6 cm)

33” (83.8 cm)

25-1/4” (64.1 cm)

36” (91.4 cm)

42” (106.7 cm)

34-1/4” (87.0 cm)

WARNING

Fire Hazard

Do not install this grill on or near combustible materials.

Doing so can result in death or fire.

Enclosure and clearance dimensions that are shown must be
used. Given dimensions provide required clearances.
The installation of this grill must conform with the current
standards CSA-Z21.58a-2005, or with local codes.

For installations in a combustible enclosure, the insulation jacket
provided with the grill must be used. A ledge on each side or a full
deck beneath the jacket must support the insulation jacket.

Copies of the standards listed may be obtained from:

CSA International

8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575

Combustible enclosure installations

2

(5.1 cm)

minimum to

open hood

11-5/8

(29.5 cm)

1-1/8

(2.9 cm)

optional custom

access doors

B

19

(48.3 cm)

35-1/2

(90.2 cm)

6

(15.2 cm)

min. clearance

for rotisserie

24

(61.0 cm)

A

12

(30.5 cm)

minimum to

any accessory

5

(12.7 cm)

7-3/8

(18.7 cm)

Gas line

locations at

rear of grill

3

(7.6 cm)

support
surface

Installation Dimensions for Built-in

Outdoor Grill with Insulation Jacket

(combustible enclosure)

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

If codes permit and a separate ground wire is used, it is
recommended that a qualifi ed electrician determine that the
ground path is adequate.

Check with a qualifi ed electrician if you are not sure whether the
grill is properly grounded.

Do not ground to a gas pipe.

A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is
required.

Recommended ground method

A grounded 3-prong outdoor outlet grounded in accordance with
the National Electrical Code ANSI/NFPA 70 or Canadian Electrical
Code (C22.1) — and local codes and ordinances.
Copies of the standards listed above may be obtained from:
CSA International

8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575

National Fire Protection Association

One Batterymarch Park
Quincy, Massachusetts 02269

3-prong polarized ground-
type outdoor outlet

3-prong ground

plug

power supply

cord

ground

prong

Electrical Requirements

Rotisserrie and Grill Light