Kenyon UL/C-UL User Manual
Page 7

For future reference, please record the serial number of your
cook top here:
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes.
The following table provides the correct voltage, amperage and frequency that must be
supplied to the cook top.
The supply must be from an individual grounded circuit that is protected by a circuit breaker
and rated per the specifications for the various models as shown in the table above.
2
Max Connected
Required Power
Minimum
Kenyon Part #
Model #
Load
Supply Input
Wire Size
B41511
MED2
3000 Watts
240 VAC/12.5A/60Hz
#12 AWG
B41516
MED2TL
2400 Watts
240 VAC/10A/60Hz
#12 AWG
B41518
MED1
1200 Watts
240 VAC/5A/60Hz
#12 AWG
B41602
CAR2
2400 Watts
240 VAC/10A/60Hz
#12 AWG
B41606
CAR1
1200 Watts
240 VAC/5A/60Hz
#12 AWG
B49511
ALP2LG
3000 Watts
240 VAC/12.5A/60 Hz
#12 AWG
B49516
ALP2SM
2400 Watts
240 VAC/10A/60Hz
#12 AWG
B49518
ALP1
1200 Watts
240 VAC/5A/60Hz
#12 AWG
!
Warning: If the electric power supply does not meet the