10
TROUBLESHOOTING GUIDE
NOTES
Case 1. Starting failure
CHECK
PROBABLE CAUSES
ACTION
Fuel tank
➔
Incorrect fuel
➔
Drain it and fill with correct fuel
Fuel filter
➔
Fuel filter is clogged
➔
Clean
Carburetor idle speed screw
➔
Out of normal range
➔
Adjust to normal range
No spark
➔
Spark plug is fouled/wet
➔
Clean/dry
➔
Plug gap is incorrect
➔
[Correct GAP .025" (0.6~0.7 mm)]
Spark plug
➔
Disconnected
➔
Retighten
Case 2. Engine starts but does not keep running/Hard re-starting
CHECK
PROBABLE CAUSES
ACTION
Fuel tank
➔
Incorrect fuel or stale fuel
➔
Drain it and fill with correct fuel
Carburetor idle speed screw
➔
Out of normal range
➔
Adjust to normal range
Muffler, cylinder(exhaust port)
➔
Carbon is built-up
➔
Wipe away
Air cleaner
➔
Clogged with dust
➔
Wash
Cylinder fin, fan cover
➔
Clogged with dust
➔
Clean
If your unit needs further service, please consult with an authorized service dealer in your area.