Snapper 3250 Watt Generator

SPECIFICATIONS

Maximum Surge Watts . . . . . . . . . . . . . . . . 4,500 Watts

Continuous Wattage Capacity . . . . . . . . . . 3,250 Watts

Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0

Rated Maximum Continuous Load Current

At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . 27.1 Amps

Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-phase

Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . 60 Hertz

Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . .103 lbs.

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.

NOTE: If equipped with inflatable tires, keep the air
pressure at the value marked on the tire or within 15 and
40 psi.

Engine Maintenance

See engine owner’s manual for instructions.

KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air
slots, some of the water will be retained in voids and
cracks of the rotor and stator winding insulation. Water
and dirt buildup on the generator internal windings will
eventually decrease the insulation resistance of these
windings.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

• Use a soft bristle brush to loosen caked on dirt or oil.

• Use a vacuum cleaner to pick up loose dirt.

• Use low pressure air (not to exceed 25 psi) to blow

away dirt. Inspect cooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.

• DO NOT expose generator to excessive moisture, dust, dirt,

or corrosive vapors.

• DO NOT insert any objects through cooling slots.

Improper treatment of generator can damage it and
shorten its life.

CAUTION

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR

• Disconnect the spark plug wire from the spark plug and place

the wire where it cannot contact spark plug.

Unintentional sparking can result in fire or
electric shock.

WARNING

• Used motor oil has been shown to cause skin cancer in

certain laboratory animals.

• Thoroughly wash exposed areas with soap and water.

Avoid prolonged or repeated skin contact with used
motor oil.