Maintenance 4, Maintenance, Airlocks – Simer Pumps 2905-04 User Manual
Page 4
For parts or assistance, call Simer Customer Service at
1-800-468-7867 / 1-800-546-7867
Maintenance
4
4. Periodically inspect the pump, system components and
sump for debris and foreign objects. Keep the sump free of
all refuse. Perform routine maintenance as required.
Risk of flooding. Flooding can cause personal
injury or property damage. This pump comes with the auto-
matic float switch mounted on the motor cover ready for oper-
ation. Do not change switch settings. Refer to the “Motor,
Switch & Cord Specifications” chart for switch settings.
MAINTENANCE
To Clean the Pump Screen:
NOTICE: Attempting to disassemble motor will void warranty.
Risk of electrical shock. Shock can burn or kill.
Always unplug the pump from the power source before servic-
ing any system component. Do not lift pump by power cord.
1. Disconnect power before servicing.
Risk of Electric shock. Shock can burn or
cause death. When servicing the system always disconnect
power cord from the electrical outlet.
2. Loosen the discharge pipe.
3. Use the pump handle to lift the pump out of the sump pit
and place the pump on a clean level surface.
4. To clean the screen, use a screwdriver to unsnap the screen
(See Figure 1), remove and rinse off the screen.
5. Re-install the screen. Be sure all the snaps catch.
6. Put the pump back into the sump pit.
7. Re-install the discharge pipe.
8. Check the system operation by filling the basin with water
and observing the pump’s operation through one complete
cycle.
Flood hazard. May cause personal injury or prop-
erty damage. Failure to make this operational check can lead to
improper operation, premature pump failure and flooding.
To Replace the Vertical Float Switch:
NOTICE: The float must be able to complete its entire cycle
without interference from any other object.
1. Mount the bracket on the switch housing with the bracket
mounting screws. See Figure 2.
Make sure the pin holds the float rod in the
switch housing; otherwise the pump will not shut off.
NOTICE: Pull gently on the rod to make sure that it cannot
come out of the switch housing.
4. Mount the switch assembly on the pump with the screw
provided.
5. Run the pump through one complete cycle to verify switch
operation is correct and that nothing interferes with the
switch’s operation.
Flood hazard. May cause personal injury or prop-
erty damage. Failure to make this operational check can lead to
improper operation, premature pump failure and flooding.
AIRLOCKS
When a pump airlocks, it runs but does not move any water.
An airlock will cause the pump to overheat and fail.
This pump has a small hole in the side of the pump housing.
See Figure 1. This is an anti-airlock valve. If you suspect an air-
lock, insert a hat pin or a pipe cleaner into the anti-airlock hole
to clean out the debris.
Anti-Airlock Valve
(Remove screen
and look under
pump for access)
Figure 1 – To clean the screen and anti-airlock valve.
Figure 2: Vertical Float Switch Replacement.