Dimensions in parentheses are in
millimeters unless otherwise specified.

S U B - Z E R O

I C E M A C H I N E

I N S T A L L A T I O N

I M P O R T A N T
N O T E

Plumbing must
conform to state
and local codes.

P L U M B I N G

R E Q U I R E M E N T S

W A T E R S U P P LY A N D D R A I N L I N E S I Z I N G / C O N N E C T I O N S

Water

Water

Ice Machine

Tubing Size up to

Temperature

Pressure

Fitting

Ice Machine Fitting

Ice Making

50°F (10°C) Min.

20 psi (137.9 kPA) Min.

1

/

4

" (6.4) ID

1

/

4

" (6.4) minimum

Water Inlet

80°F (27°C) Max.

80 psi (551.5 kPA) Max.

Copper Tubing

inside diameter

Water Outlet

3

/

4

" (19)

3

/

4

" (19) minimum

UC-15I and

Hose Barb

inside diameter

UC-15IO

Water Outlet

3

/

8

" (9.5)

3

/

8

" (9.5)

UC-15IP and

Hose

ID minimum

UC-15IPO

NOTE: If air temperature is less than 60°F (16°C), water temperature must be equal to or greater than 50°F (10°C).

IMPORTANT NOTE: Although the ice
machine has been designed to be serviced in
place, in some cases it may be necessary to
pull the unit out for service. For that reason
do not restrict access to the unit at the front,
top and bottom.

If a floor is to be installed after the ice
machine, shims the thickness of the floor
should be installed under the unit to keep the
ice machine level with the floor. Also, allow

1

/

8

" (3) clearance on each side of the unit for

protruding screw heads.

Installations on a slab: Use a Model
UC-15IPO or UC-15IP, with built-in drain
pump and pump the water to the point of
drainage. Drain pump models will pump
12 feet (3.7 m) high.

Installations over a crawl space or
basement:
If there is not enough room
behind the ice machine for a drain/waste
water receptacle, the drain will have to be
below the floor.