beautypg.com

Maintenance, Filters, Notice – Woodstock W1690 User Manual

Page 17

background image

-15-

Figure 14. 5-Micron primary filter.

Figure 15. 1-Micron secondary filter.

Figure 16. Air cleaner housing.

To change and service the filters, do these steps:

1. Unplug the air cleaner unit.

2. Move the filter retainer latch upward, remove

the primary filter and discard it. See Figure 14.

3. Remove the secondary filter and shake out the

wood dust until clean and/or wash out with warm
water and let dry. See Figure 15.

4. Vacuum out the inside of the air cleaner housing.

See Figure 16.

5. Reinstall the secondary filter when it is dry and

install a new primary filter.

6. Move the filter retainer latch downward to

lock all the filters in place.

MAINTENANCE

Filters

The amount of use has a direct bearing on when
you must change the primary air filter and service
the secondary air filter. Contact your

SHOP

FOX

®

dealer for other possible filter types

available.

Keep the air cleaner unit
unplugged during all
maintenance procedures.
Ignoring this warning may
result in serious personal
injury to you or others!

Always wear a dust mask
and safety glasses when
servicing and changing
filters. Sawdust may
cause allergic reactions
or respiratory problems.

NOTICE

DO NOT use compressed air to blow out the
secondary filter. If you do, you will damage
the filter and reduce filtering quality.

Filter Retainer Latch

MAINTENANCE