beautypg.com

Speciþ cations, Appendix, Line input to main output – Sunfire Symphonic Reference High Fidelity Control Center and Preamplifier User Manual

Page 14: Tone controls, Trigger outputs, Infrared ports, Dimensions, Net weight, Ac line operation

background image

User's Manual

14

APPENDIX

SpeciÞ cations

© 2002 SunÞ re Corporation.
All rights reserved. SunÞ re Corpora-
tion re serves the right to improve
its products at any time. Therefore,
speciÞ cations are subject to change
without notice.

Manual part number:
913-046-00 Rev A

Line input to Main output

Line Gain: 17.7 dB +/- 0.5 dB
Max level out: 7.2 Vrms at 1 KHz
Max level in: 10 Vrms at 1 KHz
Separation: > 70 dB at 1 KHz

> 50 dB at 10 KHz

Frequency Response:

20-20 KHz +/- 0.2 dB

THD:(2 V out) <0.005% 20-20 KHz
S/N (2 V out, A-weighted):

>100 dB

Crosstalk between inputs:

> 100 dB
(2 V in, 1 KHz)

Mute: > 50 dB

Phono section

Phono Gain:

MM = 41 dB +/- 1 dB
MC = 65 dB +/- 1 dB

Phono Noise:

MM > 82 dB

MC > 71 dB

Phono Input Impedance

MM 47K ohms
MC 240 ohms

Tone Controls

Tone Response 100 Hz, 10 KHz
Bass Boost +13.5 dB +/- 1 dB
Bass Cut -5.2 dB +/- 1 dB
Treble Boost +4.5 dB +/- 1 dB
Treble Cut -3.5 dB +/- 1 dB

High pass section

Freq Response: -3 dB at 80 Hz,

12 dB / octave

Trigger Outputs

12 VDC Trigger, current less than

500 mA total

Infrared ports

Optically Isolated
Standard 1/8” mini jacks
Standard 12 V signal level

Dimensions

17” W x 5.75” H x 16.5” D

Net Weight

16 lbs

AC line operation

Meets the speciÞ cations above from

90-130 VAC 50-60 Hz