Specifications – Senco PC1010 User Manual
Page 15

14
TROUBLESHOOTING
PROBABLE CAUSE
Restricted air intake filter.
Defective (reed) valve.
REMEDY
Clean.
Drain air tank and measure pump up time. Compare to
specifications. If lower, remove pump head and inspect
valve plate, clean or replace.
Symptom 10. Air compressor not making enough air.
Symptom 11. Moisture in discharge air.
PROBABLE CAUSE
Condensation in air tank caused by high level
of atmospheric humidity or air compressor is
not run long enough.
REMEDY
Drain air tank after every use. Drain air tank more often
in humid weather and use an air line filter.
15
SPECIFICATIONS
Model #
PC 1010
Motor
Horsepower
0.5HP
Voltage
115
Amperage
4
Hz.
60
Phase
Single
RPM
3400
Compressor Pump
Number of Cylinders
1
Compression Stage
1
Crankcase
Aluminum
Bearings
Ball
Cylinder
Aluminum
Valves
Reed-Single
Head
Aluminum
Filter
Insert
Motor/Pressure Switch Setting
Cut-out
120 PSI
Cut-in
90 PSI
Controls
Start/stop
Air tank
Capacity
1 gallon
Performance
CFM Air Displacement
1.4
CFM @ 40 PSI
1.0
CFM @ 90 PSI
0.6
CFM @ 100 PSI
0.5
Maximum Pressure
120 PSIG
Pump-up Time: 0-120 PSI
2 min., 30 sec.
Recovery Time:
90-120 PSI
60 seconds
Weight
Net
20 Ibs.
Dimensions
Basic LxWxH
14"x13"x10"