Installation / operation 3, Installation, Operation – Simer Pumps SMART GEYSER 2330-03 User Manual
Page 3: Airlocks
For parts or assistance, call Simer Customer Service at
1-800-468-7867 / 1-800-546-7867
Installation / Operation
3
INSTALLATION
Do not use power cord to lift motor.
Always use handle.
1. Pump should be located and should rest on level
solid foundation. Do not suspend pump by means of
discharge pipe or power cord. Keep pump inlet
screen clear.
2. Thread outlet pipe into pump body carefully to avoid
stripping or crossing threads.
a. To install with garden hose, install adapter pro-
vided with pump.
NOTICE: To keep friction as low as possible,
hose must be 5/8" or larger. Keep hose as short as
possible.
b. To install with rigid pipe, use plastic pipe. Wrap
thread with Teflon tape or use Plasto Joint Stik*.
Screw pipe into pump hand tight +1 - 1-1/2
turns.
3. If, in your application, backflow is a problem when
the pump stops, prevent it by installing a 1" NPT
check valve in the pump discharge.
4. Power Supply: Pump is designed for 115V., 60 HZ.
operation and requires an individual branch circuit
of 15 amperes or more capacity. It is supplied with a
3-wire cord set with grounding-type plug for use in a
3-wire, grounded outlet. 3 wire extension cord, of at
least 14 AWG (2mm
2
) size is suggested, with larger
sizes for runs over 25 ft (7M). For safety, pump
should always be electrically grounded to a suitable
electrical ground such as a grounded water pipe or a
properly grounded metallic raceway, or ground wire
system. Do not cut off the round grounding prong.
The pump motor is equipped with
automatic resetting thermal protector and may
restart unexpectedly. Protector tripping is indication
of motor overloading as a result of operating pump
at low heads (low discharge restriction), excessively
high or low voltage, inadequate wiring, incorrect
motor connections, or a defective motor or pump.
OPERATION
Risk of burns or death from electric shock.
Do not handle pump or pump motor with wet hands or
when standing on wet or damp surface, or in water.
Disconnect power from pump before handling, servic-
ing, or attempting to repair pump.
* Lake Chemical Co., Chicago, Illinois
The Smart Geyser
TM
is fully automatic in operation. The
“smart” controller starts the pump every 2-1/2 minutes
and causes it to run for 5 seconds. If it senses that there
is no water to the pump, it stops. If it senses water, it
continues to run until the water is pumped down to 1/4"
deep, and then it stops. It then goes into a
7-minute quick-detection cycle, starting 4 times the first
minute, twice the second minute, and once a minute for
the next 5 minutes. If by the last check it has not detect-
ed water, it resumes its cycle (running 5 seconds every
2-1/2 minutes) until it senses water again.
NOTICE: When you plug the pump into the wall outlet,
it will start and run for 5 seconds. It will then cycle as
described above.
If the unit is put in the water and started, interrupting the
water flow into the pump during the 5-second water-
sensing run will cause it to wait 2-1/2 minutes before
restarting (instead of 15 seconds).
1. The motor is equipped with an automatically reset-
ting thermal overload protector. If the motor gets too
hot, the overload protector will stop the motor
before it is damaged. When the motor has cooled
sufficiently, the overload protector will reset itself
and the motor will restart.
NOTICE: If the overload protector stops the pump
repeatedly, disconnect the power from the pump and
check it to find the problem. Low voltage, long exten-
sion cords, clogged impeller, too much back pressure
in the discharge hose (as when pumping through 50’
(15 M) of coiled hose), or extended running of pump
with no load, can all cause overheating.
2. The water being pumped cools the motor, allowing
the pump to run continuously at any depth of water
above 1/4". However, if the motor overload stops the
pump, allow it to cool for one hour before restarting.
Motor will not restart before the overload has cooled.
AIRLOCKS
When a pump airlocks, it runs but does not move any
water. An airlock will cause the pump to overheat and
fail. This pump has an anti-airlock hole in the bottom of
the pump body. If you suspect an airlock, unplug the
pump, clean out the anti-airlock hole with a paper clip
or piece of wire, and restart the pump.
NOTICE: If the outlet of the discharge hose/pipe is
submerged you must have a 1/8" hole in the discharge
hose/pipe to prevent airlock. This hole must be open to air.
NOTICE: If you move the pump or the pump airlocks, be
sure to drain the hose before trying to restart the pump.