APPENDIX A – SCI PROTOCOL AND INTERFACE
A7
SERIAL CONTROL AND MODE SWITCHES
The system configuration DIP switches S2 and S3 are located on the front edge of the SCI-MRX printed circuit board.
The power supply frame holds the SCI-MRX module. Remove the front panel of the frame to access the switches. The
momentary push-button reset switch S1 is positioned next to S3. See INTRODUCTION for details.
This chart sets the communications Baud Rate.
S2,1 S2,2
Baud
Rate
ON ON
9600
OFF ON
19200
ON OFF
38400
OFF OFF
57600
This chart sets the number of switcher inputs (sources).
S2,3 S2,4
S2,5
Input
Range
ON
ON
ON
01 - 16
OFF
ON
ON
01 - 32
ON
OFF
ON
01 - 48
OFF
OFF
ON
01 - 64
ON
ON
OFF
01 - 80
OFF
ON
OFF
01 - 96
ON
OFF
OFF
01 - 112
OFF
OFF
OFF
01 - 128
This chart sets the number of switcher outputs (destinations).
This chart indicates protocol format and logical address.
S2,9 S2,10
S2,11
Logic
Address
ON ON
ON
RS-232
∗
OFF ON
ON 01
ON OFF
ON 02
OFF OFF
ON 03
ON ON
OFF 04
OFF ON
OFF 05
ON OFF
OFF 06
OFF OFF
OFF 07
Use address 00 for RS-232. All other settings are for RS-422 operation.
Control Level
Control Panel Type
Handshaking
Reserved
Panel Scan
S2,
12 Levels S3,1 Panel
Type
S3.2 Handshaking
S3.3
S3.4 Panel
Scan
ON
8
ON Numeric ON
Enabled Reserved ON Scan
ALL
OFF
4
OFF
Alpha OFF
Disabled
OFF Scan
Active
NOTE 1 - Fixed serial communications parameters are: 8 Character bits
1 Stop bit
No Parity
NOTE 2 - Synchronous mode switching occurs on line 10 in NTSC and line 7 in PAL when reference is supplied.
S2,6 S2,7
S2,8
Output
Range
ON
ON
ON
01 - 16
OFF
ON
ON
01 - 32
ON
OFF
ON
01 - 48
OFF
OFF
ON
01 - 64
ON
ON
OFF
01 - 80
OFF
ON
OFF
01 - 96
ON
OFF
OFF
01 - 112
OFF
OFF
OFF
01 - 128
1
2
3
4
5
6
7
8
9
10
11
12
Off [down] / ON [up]
S2
1
2
3
4
S3
The Dip switch settings below are configured for a 4 level
32x32 matrix using RS-232 protocol at 38,400 baud rate.