Bg 2000 specifications, Pressure trends – Sea Frost BG 2000 User Manual
Page 30

30
BG 2000 Specifications and Operating Characteristics
115-volt 50/60 hz
230-volt 50/60 hz
Horsepower 1
HP
1HP
Refrigerant
404-a
404-a
Oil
Polyol ester oil
Polyol ester oil
Locked rotor amps
76.7
45
Current draw with pump
26.8 amps
14.10 amps
Electrical breaker
30 amp
15 amp double
pole
Maximum refrigerant charge
24 oz
24 oz
Manual reset high pressure cut-out
325 PSIG
325 PSIG
March pump
LC-3
LC-3
Integral low voltage thermostat circuit
24-volt AC
24-volt AC
Pressure trends: Gauge pressure PSIG
Water temp 60
degrees F.
Water temp 80
degrees F.
Hi Pressure
175
190
Low Pressure (Warm Plates)
30
30
Low pressure (Cold Plates)
7 to 5
7 to 5
Pressures are approximate: High pressure will momentarily rise beyond operating
pressure until the expansion valve starts to restrict flow. Condensing pressure will be
15 degrees above water temp.
Low pressure will drop from equalized at start up to settle at the indicated low reading in
a period of about 45 minutes depending on the number of plates and starting
temperature. Proper thermostat set up should cycle the compressor in this low-
pressure range.
THE EXPANSION VALVES HAVE BEEN FACTORY ADJUSTED FOR OPTIMUM
PERFORMANCE. DO NOT ADJUST THIS VALVE FOR ANY REASON.
INCORRECT SETTINGS MAY RUIN THE COMPRESSOR!