For more information on State On-Demand Water Heaters, contact:
State Water Heaters
500 Tennessee Waltz Parkway
Ashland City, TN 37015

800-365-0024 Toll-free USA

www.statewaterheaters.com

SRGSS02007

April 2010R

Specifications

Specifications are subject to change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.

* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

** for commercial and hydronic applications requiring higher temperatures

Model

305

200/201 Series

505

200/201 Series

705

Minimum Gas Consumption Btu/h

15,000

19,000

Maximum Gas Consumption Btu/h

180,000

199,000 Natural Gas

190,000 Propane Gas

237,000

Hot water capacity (Min - Max) *

0.6 - 7.5 GPM

(2.3 - 28.4 L/min)

0.6 - 9.4 GPM

(2.3 - 35.5 L/min)

0.6 - 9.8 GPM

(2.3 - 37 L/min)

Interior Hot Water Capacity (45° rise)

6.6 GPM (25.0 L/min)

7.4 GPM (28.0 L/min)

Natural Gas

7.1 GPM (26.9 L/min)

Propane Gas

8.8 GPM (33.5 L/min)

Default Temperature Setting (no controller)

120º F (49º C)

Exterior Hot Water Capacity (45° rise)

7.4 GPM (28.0 L/min)

8.7 GPM (33.1 L/min)

Setting

Maximum Temp Setting (Commercial**)

160º F (71º C)

185º F (85º C)

Minimum Temperature Setting

98º F (37º C)

Efficiency Rating / Energy Factor

84% / .82 E.F.

84%/N.A.

Electrical
Consumption

Normal (Indoor/Outdoor)

65 W/50 W

79 W/55 W

99 W/72 W

Anti-frost Protection

100 W

116 W

Minimum Gas Supply
Pressure

Natural Gas

5.0 inch W.C.

Maximum Gas Supply
Pressure

Natural Gas

10.5 inch W.C.

Propane

13.5 inch W.C.

Type of Appliance

Direct Vent, Temperature controlled continuous flow gas hot water system.

Approved Gas Type

Natural Gas or Propane - Ensure unit matches gas type it's being installed on.

Ignition System

Direct Electronic Ignition

Water Temperature Control

Simulation Feedforward and Feedback.

y

Maximum Water Supply Pressure

150 PSI

Energy Star® Qualified

Yes

Yes

No

6.6 GPM (25.0 L/min)

Temperature Controller Default Temperature

104º F (40º C)

Maximum Temp Setting (Residential)

Selectable at 120º F (49º C) or at 140º F (60º C)

140º F (60º C)

Weight (Indoor/Outdoor)

Indoor Unit 50 lb (23kg) Outdoor Unit 46 lb (21 kg)

55 lb (25 kg)

Noise level

49dB

Standby 2

W

Propane

8.0 inch W.C.

Operation

With or without temperature controls, mounted in kitchen, bathroom, etc.

Connections

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4"

Electric Connections

Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)

Water Suppl Pressure

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum

performance)

Temperature Control Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

By-Pass Control

Fixed

Electronic

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

0

25

50

75

100

125

150

Water Flow (gpm)

delta T - Temperature Rise (ºF)

705

505

305

ANSZ21.10.3 CSA 4.3

224259 SRGSS02007 4