beautypg.com

Troubleshooting guide – STA-RITE DURA-JET JSAEL-2A User Manual

Page 11

background image

11

TROUBLESHOOTING GUIDE

Read and understand safety and operating instructions in this manual

before doing any work on pump!

A. PUMP DOES NOT OPERATE

1. Check GFCI for proper operation according to GFCI manufacturer’s in-

structions.

2. Check for plugged impeller. Follow disassembly/assembly instructions

under “Pump Service”, Page 8.

3. Consult dealer/installer or service representative.

B. IMPROPER JET ACTION

1. Check for blocked fittings. Blocked fittings will cause poor flow and poor jet

action.

2. Consult dealer/installer or service representative.

C. EXCESSIVE AIR IN SYSTEM – PUMP LOSES PRIME

1. Make sure water level in spa is at least 2" (51 mm) above top of jets with sys-

tem not operating.

2. Make sure there are no leaks in suction piping.
3. Make sure there is no vortex (whirlpool) at the suction.
4. Consult dealer/installer or service representative.

D. CIRCUIT BREAKER IN HOME PANEL TRIPS REPEATEDLY

1. Breaker must be of adequate capacity.
2. For GFCI breaker: test according to GFCI manufacturer’s instructions.
3. Make sure no other lights and appliances are on circuit.
4. Consult dealer/installer or service representative.