beautypg.com

Strong Enterprises FOLLOW SPOTLIGHT 48057 User Manual

Page 9

background image

REMOVE THE PLASTIC COVER from the xenon bulb. Store the protective cover and the

original bulb packing in a secure location. The spare anode adapter (65199) is for use with an OSRAM 700

watt bulb (XBO700W/HS OFR) should such a bulb be used as a replacement.

SECURE THE LAMPHOUSE COVER with the (4) tamperproof screws using the special

screwdriver provided. The cover must be securely in position to actuate the interlock switch and permit lamp

ignition.

IT IS RECOMMENDED to establish a routine for periodically checking all electrical connec-

tions for tightness, particularly those at the bulb. A loose connection in the DC circuit will cause failure of the

contacts and leads, and may damage the bulb.