1 test for prominent discrete tones (pdts), 9 electromagnetic immunity, Test for prominent discrete tones (pdts) – Seagate BARRACUDA XT ST33000651AS User Manual
Page 19: Electromagnetic immunity
Barracuda XT SATA Product Manual, Rev. D
19
Drive Specifications
2.8.1 Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-
7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of
tone ratios according to Annex D of the ECMA-74 standards.
2.9 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 5 Radio frequency environments
Test
Description
Performance level Reference
standard
Electrostatic
discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN61000-4-2: 95
Radiated RF
immunity
80 to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @
200Hz
A
EN61000-4-3: 96
ENV 50204: 95
Electrical fast
transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN61000-4-4: 95
Surge immu-
nity
± 1 kV differential, ± 2 kV common, AC mains
B
EN61000-4-5: 95
Conducted RF
immunity
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz
sine
A
EN61000-4-6: 97
Voltage dips,
interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94