26.
GROUP FADERS
Long-throw master faders for each Group. Unity gain is
at the top of their travel.
27.
GROUP OUTPUTS
The output from each Group is driven by a ground-
compensated amplifier and fed to standard
1
⁄
4
" 3 pole
A gauge jack sockets.
28.
GROUP INSERTS
These allow external processing equipment to be in-
serted into the Group signal path. The
1
⁄
4
" 3 pole A
gauge jack sockets are by-passed except when a plug
is inserted.
29. PFL
When the PFL switch is pressed, the pre-fade Group
signal is fed to the Control Room Monitors and Head-
phones, where it replaces the selected source. The
PFL/AFL LED on the master section illuminates to
warn that the monitor and the meters are now respond-
ing to the PFL/AFL selection and the PFL LED on the
Group lights to identify the active Group.
30. SUBGROUP
MIX/MONO
The MIX switch routes the Groups as odd and even
pairs to the stereo Mix, or if the MNO switch is pressed
the groups are fed equally to both sides of the stereo
Mix.
31.
BARGRAPH METERS
A 16-segment, three colour bargraph meter provides
visual monitoring of output level for each Group. The
meter is factory set to a PEAK characteristic, but may
be changed internally to a VU characteristic. Please re-
fer to the Selectable Options section (Page 31) for
details.