ELECTRICAL CONNECTION

• Remove the cover from the Field Wiring Compartment with a

phillips screwdriver.

• Feed the Power Supply Cable through the electrical knockout.

Connect the Power Supply Cable to the range- hood cable. At-
tach the Power Supply Cable grounding lead to the green screw
provided. Attach the White lead of the power supply to the
White lead of the rangehood with a twist-on type wire connec-
tor. Attach the Black lead of the power supply to the Black
lead of the rangehood with a twist-on type wire connector.

• Replace the cover.

Chimney assembly

Upper exhaust chimney
• Slightly widen the two sides of the upper flue and hook them

behind the brackets 7.2.1, making sure that they are well
seated.

• Secure the sides to the brackets using the 4 screws 12c sup-

plied.


Lower exhaust chimney
• Slightly widen the two sides of the flue and hook them be-

tween the upper flue and the wall, making sure that they are
well seated.

• Fix the lower part laterally to the hood body using the 2 screws

12c supplied.

• On the recirculation version, fit the directional grids 8a – 8b in

their housings making sure that the directional symbols are to-
wards the top and front of the hood. Also make sure that they
are correctly inserted in the connection extension pieces 14.1.

12c

8a

2.1

2.2

2

8b

7.2.1

12c

Power supply cable

Green

Ground

screw

Ground wire