beautypg.com

Quick kleen, Fan chamber, How to replace worn brush strips – Sanitaire 880 User Manual

Page 6: Brush roll

background image

6

7. Replace Cup

and Swing

Lid Shut

5. Remove

Cup

6. Empty

Cup

5. Reach in, grasp the dust cup and pull it out of the support.
6. Empty contents in a suitable container. (If desired, the cup

can be washed in warm water using a mild soap solution.
Be sure the cup is completely dry before replacing.)

7. Place the cup into the support, swing the lid shut, and fasten

each latch.

8. Hook clip to top of bag (refer to item 1).

Quick Kleen

®

Fan Chamber

(880 Series Only)

CAUTION: Turn off the switch and unplug the

electrical cord before cleaning.

The clear, removable fan chamber

cover provides easy inspection,

cleaning, and maintenance of

the fan chamber. Removing the

cover provides easy access to the

motor fan. Grease buildup, dirt, or

other obstructions, visible through

the fan cover, should be removed.

To clean the fan area, take off the

chrome bottom plate by releasing

the two cam locks (see Brush Roll

Belt, Figure 1 and 2). Remove the belt from the motor pulley,

then loosen and remove the screws on either side of the fan

cover, as indicated by the arrows. Push the cam locks outward

against the wheels to lift the cover from the cleaner base. Dirt

and obstructions can easily be cleared; however, caked grease

may need to be scraped from the cover and the cleaner. If

the fan does not turn freely, it also should be removed for

cleaning. To remove the fan, place a wrench over the motor

pulley. Hold the fan blades with one hand and turn the wrench

counterclockwise. Remove the motor pulley and lift the fan off

the motor shaft. Clean the area and replace the fan over the

motor shaft. Tighten the motor pulley snugly clockwise with

the wrench. If necessary, replace the fan cover or the gasket

with replacement parts.

Be sure the gasket is in place. Reposition the fan cover by

first placing the exhaust end into place between the large rear

wheels. Seat the fan cover firmly. Next replace the belt and

bottom plate as the pressure from the bottom plate helps seal

the fan cover. Start the two screws by hand to be sure they

are straight, then tighten.
Order fan chamber cover replacement kit (fan cover,

gasket, two screws) Part No. 52334.

A B C D

F

E

D

TO RE-ASSEMBLE

7. Slide in new brush strip of same length (rounded end

first) Fit track on either side of brush strip into brush roll

slot (F).

Replace second brush strip from opposite end of brush

roll (E).

8. Replace shaft
9. Align indentation on bearing retainer with brush strip on

both ends of brush roll (D).

(replace shaft washer on sleeve bearing assembly)

1. Remove rubber end cap cover from one end (A).
2. Unscrew locknut (B).
3. Remove end cap (sleeve bearing brush roll assembly

includes a shaft washer, not pictured) (C).

4. Remove bearing retainer (D).
5. Push shaft through opposite end (E).
6. Pull out worn brush strip with pliers (F).

How To Replace Worn Brush Strips

(chromed steel brush roll)

CAUTION: Turn off the switch and unplug the

electrical cord before replacing brush
strips.

New brush strips are supplied in sets of two, one long and
one short. To replace, remove bottom plate and belt (see
How To Change Belt). Then, grasp center of brush roll and
lift to remove.

Brush Roll

As the brush roll rotates, it sweeps and combs the carpet nap.
Remove hair and threads from the brush roll so it continues
brushing the carpet nap. When the bristles of the brush roll no
longer touch a straight edge held across the bottom plate, the
brush roll is ineffective because the bristles no longer touch
the carpet nap. To maintain the most effective cleaning, use a
new wood brush roll. Replace the brush strips on the chromed
steel brush roll.