Installation

39971

16

Electrical Requirements

NOTE: The wiring diagram is located in the
control hood.

Figure 17

120 Volt, 60 Hertz, with 3 Prong Grounding
(Earthing) Plug

The washer is designed to be operated on a separate
branch, polarized three-wire, effectively grounded
(earthed) 120 Volt, 60 Hertz, AC (alternating current),
circuit protected by a 15 ampere fuse, equivalent
fusetron or circuit breaker.

The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to Figure 18
for determining correct polarity of the wall receptacle.

Do not modify the plug provided with the washer – if
it will not fit the outlet, have a proper outlet installed
by a qualified electrician.

Figure 18

D009I

To reduce the risk of fire, electric shock or
personal injury, all wiring and earthing
MUST conform with the latest edition of the
National Electrical Code, ANSI/NFPA 70, and
such local regulations as might apply. It is
the customer’s responsibility to have the
wiring, fuses and circuit breakers checked
by a qualified electrician to make sure your
home has adequate electrical power to
operate the washer.

W129

WARNING

D009I

DO NOT OVERLOAD CIRCUITS
DO NOT USE ADAPTER
DO NOT USE AN EXTENSION CORD

D090I

1

L1

2

Ground

3

Neutral Side

4

Round Grounding Prong

5

Neutral

STANDARD 120 VOLT, 60 HERTZ, 3 WIRE

EFFECTIVELY GROUNDED CIRCUIT

1

2

3

4

5

120 ± 12

V.A.C.

120 ± 12

V.A.C.

0 V.A.C.