INTERNAL MODIFICATIONS

WARNING: All modifications must be performed by quali-
fied service technicians. Voltages in this equipment are haz-
ardous to life. No user-serviceable parts inside. Refer all
servicing to qualified service personnel. The safety certifica-
tions of the SCM800 do not apply when the operating volt-
age is changed from the factory setting.

ABOUT PRINTED CIRCUIT BOARD MODIFICATIONS

S

A jumper is represented by “X” on the printed circuit

board legend, a resistor is represented by an “R.”

S

The first number in the reference designator indicates

the channel number; i.e., R1027 refers to a Channel 1

resistor, and X7216 refers to a Channel 7 jumper, etc.

S

Components in the Master section are preceded by

the number “9” (X901, etc.).

S

The circuit board contains holes where resistors are

to be added.

S

A single drop of solder can serve as a jumper between

adjacent jumper pads.

S

All Channel modifications in this section use

Channel 1 as an example.

REMOVING THE TOP COVER

To gain access to the main printed circuit board, remove the

eight Phillips head screws securing the top cover to the chas-

sis and remove it. Most internal modifications can be made

from the top of the main board.

MODIFYING THE SCM800 FOR 220–240 VAC, 50/60 HZ OPERATION

The SCM800 can be internally modified to operate on 230 Vac,

50/60 Hz power.
NOTE: The supplied cord uses Harmonized IEC Cordage with

the following color coding: Brown = Line, Blue = Neutral,

Green/Yellow = Ground. For systems requiring other mains

connectors, obtain a power cord with an IEC 320 type mating

connector for connection to the SCM800, and an appropriate

plug on the other end for connection to the mains.

Procedure:
1. Disconnect the SCM800 from the AC power source.
2. Remove the top cover.
3. Locate Voltage Selector switch SW903 adjacent to power

transformer T901. Use a screwdriver to turn the center ro-

tor on the SW903 to the 230V position.

4. Locate Fuse F901 and remove it. Replace it with a 100

mA, 250 V, time delay fuse for 230V operation. Fuse part

numbers are listed in following table:

Fuse Type

Shure Part No.

Littelfuse Part No.

100 mA, 250 V

80C258

218.100

200 mA, 250 V

80BC8196

239.200

5. Replace the power cord with a cord rated for for 230V op-

eration, i.e., an IEC appliance connector on the equip-

ment end and a CEE 7/7 (“Schuko”) mains connector on

the other.

MODIFYING THE SCM800E FOR 100–120 VAC, 50/60 HZ OPERATION

The SCM800E can be internally modified to operate on 120

Vac, 50/60 Hz power.
NOTE: The supplied cord uses Harmonized IEC Cordage with

the following color coding: Brown = Line, Blue = Neutral,

Green/Yellow = Ground. For systems requiring other mains

connectors, obtain a power cord with an IEC 320 type mating

connector for connection to the SCM800E, and an appropriate

plug on the other end for connection to the mains.

Procedure:
1. Disconnect the SCM800E from the AC power source.
2. Remove the top cover.
3. Locate Voltage Selector switch SW903 adjacent to power

transformer T901. Use a screwdriver to turn the center ro-

tor on the SW903 to the 120V position.

4. Locate Fuse F901 and remove it. Replace it with a 200

mA, 250 V time delay fuse for 120 V operation. Fuse part

numbers are listed in the following table:

Fuse Type

Shure Part No.

Littelfuse Part No.

200 mA, 250 V

80BC8196

239.200

100 mA, 250 V

80C258

218.100

5. Replace the power cord with a cord rated for 120V opera-

tion, i.e., an IEC appliance connector on the equipment

end and a mains connector suitable for 120V operation on

the other.