SMC Networks M8501 User Manual
Page 66
Troubleshooting
M8501 and M8502 ACL Tape Drive Installation and User’s Guide — 529972-001
6- 10
Fault Symptom Codes (FSCs)
Deactivation of a drive
failed
700F
C, G
The Control task is indicating that a
request to deactivate a drive failed;
reason is not known.
Drive removal failed
7010
C, G
The Drive task is indicating that a request
to power-down a drive failed; reason is
not known.
Drive is Active failed
7012
C, G
The Drive task is indicating that a request
to determine if a drive is executing a host
command failed; reason is not known.
Control Com
Unidentified
7013
C, G
During HotSwap, a command response
from the Control task could not be
associated with any outstanding
command.
Drive status updated
failed
7014
C, G
The Drive task is indicating that a request
to determine the current state of a drive
failed; reason is not known.
Loader command
execution failed
7015
C, G
The Loader task is indicating that a
command has failed to complete
successfully.
Sequential command
execution failed
7016
C, G
The Sequential task is indicating that a
command has failed to complete
successfully.
Destination Xchg for
msg. was Null
7017
C, G
Attempting to send a message to a task,
but the argument exchange pointer was
Null.
Bad src mod in peg
msg
7018
C, G
A message was received from a remote
module, but the module number was out
of range.
A Peg message has a
pointer to Null.
7019
C, G
Peg message wrapping a Null msg. ptr.
Xchg conversion
failed
701A
C, G
Attempt to determine the module number
containing the task that is returning a
command response failed.
Invalid L-drive number
to convert
701B
C, G
Attempt to send a command to a drive,
but the logical drive number is out of
range.
Invalid P-drive number
to convert
701C
C, G
Attempt to send a command to a drive,
but the physical drive number is out of
range.
Invalid mod number to
convert
701D
C, G
Attempt to send a command to a drive in
a remote module, but the module number
is out of range.
Table 6-2. Fault Symptom Codes
Message
FSC ERP