TROUBLEShOOTING

16.

PROBLEM

POSSIBLE CAUSE

SOLUTION/REASONS

No reading on the am-

meter.

Clamps are not making a

good connection.

2-amp charge rate is be-

ing used.

Check for poor connec-

tions to battery and frame.

Make sure connecting

points are clean.
Ammeter may show no

activity at the 2-amp

charge rate.

No reading on ammeter.

Fan inside wheel charger

appears to not be work-

ing.

No power at receptacle.

AC cord and/or extension

cord is loose.

Check for open fuse or

circuit breaker supplying

AC outlet.
Check power cord and

extension cord for loose

fitting plug.

Circuit breaker in charger

cycles on and off with a

clicking sound.

Shorted battery clamps.

Shorted battery.

Charger leads reversed.
Volt/Amp Selector Switch

set to the START position.

Circuit breaker cycles

when current draw is

too high. Separate the

clamps. Check for worn

cables and replace if

needed.
Have battery tested by a

Sears or other qualified

service dealer.
Correct Connections.
Correct Volt/Amp Selector

setting.

Short start cycle when

cranking engine.

Drawing more than 250

amps for a period of 3

seconds or less.

Failure to wait for 4

minutes (240 seconds)

between cranks.

Crank time varies with the

amount of current drawn.

If cranking draws more

than 250 amps, crank

time may be less than 3

seconds.
Wait 4 minutes before

next crank.

Ammeter reads less than

selected charge rate when

charging a discharged

battery.

Extension cord too long or

wire gauge too small.
Weak cell or sulfated plate

in battery.

Battery is only partially

discharged.

Use shorter or heavier

gauge extension cord.
Sulfated battery will

eventually take a normal

charge if left connected. If

the battery will not take a

charge, have it tested by

a Sears or other qualified

service dealer.

Continue charging battery.

Charger makes a loud

buzz or hum.

Transformer laminations

vibrate (buzz).
Shorted diode (hum).

Continue charging. Buzz

is not abnormal.
Have charger tested by a

Sears or other qualified

service dealer.

If the above solutions do not eliminate the problem

call toll-free from anywhere in the U.S.A.

1-800-SEARS-64 (1-800-732-7764)

7 AM to 4:30 PM Central Time Monday through friday