beautypg.com

Installation, Technical information, The rating plate – Smeg DUCO4SS User Manual

Page 23: Electrical connection, Instructions for the installer

background image

Instructions for the installer

25

15. INSTALLATION

15.1 Technical

information

Oven type

See rating plate

Electrical

connections

220-240 V - 380-415 V 2N - 380-415 V 3N ~ 50 Hz

Required protection fuse for the oven

30 Amps

OVEN RATING

Ovens

Electric

Maximum electrical power

6.1 kW

Oven

grilling

Electric

Large grilling power

3.0 kW (230 V)

Small grilling power

1.8 kW (230 V)

Ovens lightings

25 W (230 V)

OVEN CAVITY DIMENSIONS

Large oven

Small oven

Height

(cm)

34

23

Width

(cm)

46

46

Depth

(cm)

40

40

Internal

volume

(cm

2

) 62560

42320

15.2 The

rating

plate

CHECK THAT MAINS VOLTAGE AND POWER CABLE RATINGS ARE AS PER THE
INDICATIONS PROVIDED ON THE LABEL ATTACHED TO THE OVEN DOOR FRAME.
THIS LABEL MUST NEVER BE REMOVED.

Model

Serial N°

15.3 Electrical

connection

IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE
METHODS REQUIRED BY SAFETY RULES.

WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE
COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH
APPLICABLE REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.

IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN,
FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT
IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.

IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND
SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS THESE COULD
CAUSE OVERHEATING AND RISK OF BURNS.

IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT
BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN 3 MM IN AN
EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE OVEN.