beautypg.com

Specifications, If thin lines appear on the screen, Self-diagnosis function – Sony HMD-A240 User Manual

Page 8

background image

8

If thin lines appear on the screen

(damper wires)

These lines do not indicate a malfunction; they are a normal
effect of the Trinitron picture tube with this monitor. These are
shadows from the damper wires used to stabilize the aperture
grille. The aperture grille is the essential element that makes a
Trinitron picture tube unique by allowing more light to reach the
screen, resulting in a brighter, more detailed picture.

Self-diagnosis function

This monitor is equipped with a self-diagnosis function. If there is
a problem with your monitor or computer, the screen will go
blank and the 1 (power) indicator will either light up green or
flash orange. If the 1 (power) indicator is lit in orange, the
computer is in power saving mode. Try pressing any key on the
keyboard or moving the mouse.

x If the 1 (power) indicator is green

1

Disconnect the video input cable or turn off the
connected computer.

2

Press the 1 (power) button twice to turn the monitor
off and then on.

3

Move the joystick

, for 2 seconds.

If all 4 color bars appear (white, red, green, blue), the monitor is
working properly. Reconnect the video input cables. Adjust the
brightness and contrast, and check the monitor. If the fault still
exists, check your computer.
If the color bars do not appear, there is a potential monitor failure.
Inform your authorized Sony dealer of the monitor’s condition.

x If the 1 (power) indicator is flashing orange

Turn the monitor OFF and then ON.

If the 1 (power) indicator lights up green, the monitor is working
properly.
If the 1 (power) indicator is still flashing, there is a potential
monitor failure. Count the number of seconds between orange
flashes of the 1 (power) indicator and inform your authorized
Sony dealer of the monitor’s condition. Be sure to note the model
name and serial number of your monitor. Also note the make and
model of your computer and graphics board.

Specifications

HMD-A240
CRT

0.24 mm aperture grille pitch (center)
17 inches measured diagonally
90-degree deflection
FD Trinitron

Viewable image size

Approx. 327

×

243 mm (w/h)

(12

7

/

8

×

9

5

/

8

inches)

Viewing image

Approx. 406 mm (16 inches)

Resolution

Maximum

Horizontal: 1280 dots
Vertical: 1024 lines

Recommended

Horizontal: 1024 dots
Vertical: 768 lines

Standard image area

Approx. 312

×

234 mm (w/h)

(12

3

/8

×

9

1

/4 inches)

Deflection frequency*

Horizontal: 30 to 70 kHz
Vertical: 48 to 120 Hz

AC input voltage/current

100 - 120 V, 50 - 60 Hz, Max. 1.7 A

Power consumption

Approx. 100 W

Operating temperature

10 ºC to 40 ºC

Dimensions

Approx. 422

Ч

432

Ч

426 mm (w/h/d)

(16

5

/8

Ч

17

1

/8

Ч

16

1

/2 inches)

Mass (Monitor Weight)

Approx. 18 kg (39.1 lb)

Plug and Play

DDC2B/DDC2Bi,
GTF

Supplied accessories

Power cord (1)
Warranty card (1)
This instruction manual (1)

HMD-A440
CRT

0.24 mm aperture grille pitch (center)
19 inches measured diagonally
90-degree deflection
FD Trinitron

Viewable image size

Approx. 365

×

274 mm (w/h)

(14

3

/

8

×

10

7

/

8

inches)

Viewing image

Approx. 456 mm (18 inches)

Resolution

Maximum

Horizontal: 1920 dots
Vertical: 1440 lines

Recommended

Horizontal: 1280 dots
Vertical: 1024 lines

Standard image area

Approx. 352

×

264 mm (w/h)

(13

7

/8

×

10

3

/8 inches)

Deflection frequency*

Horizontal: 30 to 96 kHz
Vertical: 48 to 170 Hz

AC input voltage/current

100 - 120 V, 50 - 60 Hz, Max. 2.0 A

Power consumption

Approx. 130 W

Operating temperature

10 ºC to 40 ºC

Dimensions

Approx. 461

Ч

479

Ч

471 mm (w/h/d)

(18

1

/8

Ч

19

1

/8

Ч

18

1

/2 inches)

Mass (Monitor Weight)

Approx. 26 kg (57 lb)

Plug and Play

DDC2B/DDC2Bi,
GTF

Supplied accessories

Power cord (1)
Warranty card (1)
This instruction manual (1)

*

Recommended horizontal and vertical timing condition
• Horizontal sync width should be more than 1.0 µsec.
• Horizontal blanking width should be more than 3.0 µsec.
• Vertical blanking width should be more than 500 µsec.

Design and specifications are subject to change without notice.

Damper