beautypg.com

Heating cartridge check (at contactor) – Southbend StratoSteam STRE-5D User Manual

Page 25

background image

S

TRATO

S

TEAM

E

LECTRIC

C

OUNTERTOP

S

TEAMER

S

ERVICE

O

WNER

S

M

ANUAL

1189951

(10/08) P

AGE

25

OF

56

Figure 14

Heating Cartridge Check (at Contactor)

L1

A

L2

B

L3

C

Top of

Steamer

Ohms

1. DISCONNECT POWER AT CIRCUIT BREAKER.

2. Turn Control Lever to OFF.

3. Remove right side panel of steamer.

4. DO NOT DISCONNECT HEATING-CARTRIDGE LEAD WIRES FOR THIS TEST.

5. Using a multimeter, check the resistance across contactor terminals as specified in the following table:

Model STRE-3D

Model STRE-5D

Allowable Resistance (Ohms)

Allowable Resistance (Ohms)

Three-Phase

Single-Phase Three-Phase

Single-Phase

Serial-

Plate

Voltage

A-B and B-C

A-C

A-C

A-B and B-C

A-C

A-C

208

10 to 12

14 to 16

5 to 6

8 to 10

11 to 13

4 to 5

220

12 to 13

15 to 18

6 to 7

9 to 11

13 to 15

5 to 6

240

14 to 16

18 to 21

7 to 9

11 to 13

15 to 17

6 to 7

480

55 to 64

73 to 85

29 to 34

45 to 52

60 to 70

24 to 28

6. If the measured resistance at the contactor is not in the specified range, disconnect all the heating cartridges

from the contactor. Measure the resistance across the leads each cartridge. Replace any cartridge that
shows either an open or short circuit.