beautypg.com

Warnings – Superior SDVI User Manual

Page 17

background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5. Locate the pilot by looking over the top of the left front log. A

blue flame will be seen when the pilot is lit.

6. Turn the gas control knob counter-clockwise to the

"PILOT" position.

7. Push the knob all the way in and hold in that position. Immediately

light the pilot by pressing the igniter button several times until
pilot is lit. Continue to hold the knob in for about 30 seconds
after the pilot is lit. Release knob and it will pop back out. Pilot
should remain lit. If it goes out, repeat steps 4-8 holding knob
in an additional 15 seconds after pilot is lit. If knob does not
pop out when released, stop and immediately call your service
technician or gas supplier. If the pilot will not stay lit after several
tries, turn the gas control knob to "OFF" and call your service
technician or your gas supplier.

8. After pilot is lit, turn gas control knob counter-clockwise
to "ON." Knob can only be turned to "ON" if the knob

has popped out.

9. To turn burner on, turn "ON/OFF" rocker switch to "ON" or

set the thermostat to the desired temperature above room
temperature.

10. Adjust the flame height (and heat output) by turning the flame

height knob clockwise for full flame and counter-
clockwise for reduced flame.

11. Turn on the electric power to the appliance and set the blower

to the desired air flow after it turns on when the appliance
reaches operating temperature.

TO TURN OFF GAS TO APPLIANCE

1. Turn off the "ON/OFF" rocker switch and/or thermostat (if

installed) to its lowest setting.

2. Turn off electric power to the appliance if service is to be

performed.

3. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.

This appliance needs fresh air for safe operation and must be

installed so there are provisions for adequate combustion and

ventilation air.

SHUTDOWN PROCEDURE

To turn off the burner, turn the rocker switch to "OFF" or adjust

the thermostat (if installed) to a setting below room temperature.

The pilot will remain lit for future burner ignition. For complete

shutdown, see "TO TURN OFF GAS TO APPLIANCE" above.

Pilot Assembly

Thermopile

Veilleuse à gaz

Igniter (electrode)

Allumeur

Thermocouple

Gas Pilot Hood

Robertshaw Millivolt Gas Valve

TP/TH

TH

TP

Gas Control Knob

(Pilot / On / Off)

O

FF

O

N

Piezo Igniter

Allumeur

ON/OFF Switch

Interrupteur

Flame Height Control

Knob (HI/LO)

Figure 16

WARNINGS

Operation of this appliance when not connected

to a properly installed and maintained venting

system can result in carbon monoxide (CO)

poisoning and possible death.

Carbon monoxide poisoning – early signs of

carbon monoxide poisoning resemble the flu

with headaches, dizziness, or nausea. If you

have these signs, get fresh air at once! Have the

heater inspected by a qualified service techni-

cian. Some people are more affected by carbon

monoxide than others. These include pregnant

women, people with heart or lung disease or

anemia, those under the influence of alcohol,

and those at high altitudes.