InstallatIon Manual

PoWER CoRD ConnECtIons

4-WIre ConneCtIon InstruCtIons
Before wiring the range, review the suggested power source location

drawing in Figure 2. If connecting to a 4-wire electrical system for a

new branch-circuit or mobile home use a 4-wire connection.

Follow the power supply cord kit manufacturer’s Installation

Instructions and install the strain relief clamp on the cord. See

Figure 8.

Connect the end connectors for line 1, line 2 and neutral and

tighten securely to the terminal block. See Figure 9.

IMportant

DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal

block. Electrical failure or loss of electrical connection may

occur if these 3 nuts are loosened or removed.

You must disconnect the ground strap. Remove the factory

installed ground screw and plate to release the copper ground

strap from the frame of the range. Cut and discard the copper

ground strap and plate. KEEP the ground screw. See Figure 9.

Connect the green ground wire lead with the eyelet to the frame

of the range with the ground screw using the same hole in the

frame where the ground screw was originally installed. See

Figure 9.

Make sure all screws are tightened securely and replace the

rear access cover and secure with screw. See Figure 7.

3-WIre ConneCtIon InstruCtIons

For existing installations ONLY, refer to Figure 10.

Follow the power supply cord kit manufacturer’s Installation

Instructions and install the strain relief clamp. See Figure 10.

Connect the end connectors for line 1, line 2 and neutral and

tighten securely to the terminal block. See Figure 10.

IMportant

DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal

block. Electrical failure or loss of electrical connection may

occur if these 3 nuts are loosened or removed.

A ground strap is installed on this range which connects the

center terminal of the neutral terminal block to the range

chassis. The ground strap is connected to the range by the

center, lowest screw. See Figure 10. The ground strap must

not be removed unless National, State or Local Codes do not

permit use of a ground strap.

note:

If the ground strap is removed for any reason, a

separate ground wire must be connected to the separate ground

screw attached to the range chassis and to an adequate ground

source.

Make sure all connections are tightened securely and replace

the rear access cover and secure with screw. See Figure 7.

3 & 4-WIre perManent WIre ConneCtIons

3–wire permanent connection – follow steps 1, 2 and 5 below.

4–wire permanent connection – follow all steps below.
Before wiring the range, review the suggested power source location

drawings in Figure 2. If connecting to a 4-wire electrical system:

Follow the manufacturer’s Installation Instructions for installing

the strain relief clamp.

Strip insulation away from the ends of the permanent wiring

for line 1, line 2 and neutral; also strip ground wire on 4-wire

connections. Tighten all 3 or 4-wire leads to the terminal block.

Follow wire locations shown in Figure 11.

IMportant

DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal

block. Electrical failure or loss of electrical connection may

occur if these 3 nuts are loosened or removed.

note:

For 3-wire permanent connection skip steps 3 and 4

and continue with step 5.

Disconnect the ground strap. Remove the factory installed

ground screw and plate to release the factory installed copper

ground strap from frame of the range. Cut and discard the

copper strap from the terminal block. KEEP the ground screw,

ground plate and go to step 4.

Connect the green ground wire lead to the frame of the range

using the ground screw and plate as shown in Figure 12. Be sure

to install using the same hole in the frame where the ground

screw was originally installed.

Make sure all connections are tightened securely and replace

the rear access cover. See Figure 7.

note:

Non-terminated field wire compression connections

must be set at approximately 90 in./lb.

4-WIre ConneCtIon

Terminal block

wh

ite

gre

en

Connect green

insulated copper

ground wire with

ground screw here.

Cut ground strap.

Discard ground

strap and ground

plate.

Connect neutral

(white or center) here.

Connect

line 1 here.

Connect line 2 here.

blac

k

Note:

Install strain

relief clamp. Center

or white wire must

always be attached to

the center terminal on

block.

A user supplied strain

relief clamp must be

installed at this

location. It requires 1

3/8" (3.5 cm) diameter

cord kit hole.

red

Figure 9

-WIre ConneCtIon

Figure 10

Ground strap

Terminal block

Note: Install strain
relief clamp. Center
must always be
attached to the
center terminal on
block.

Connect neutral
here.

Connect line
1 here.

Connect line 2 here.

A user supplied
strain relief clamp
must be installed
at this location. It
requires 1 3/8"
(3.5 cm) diameter
cord kit hole.