beautypg.com

Maintenance (continued) – Shindaiwa PowerBroom PB270 User Manual

Page 15

background image

15

spark plug gap--all models

Remove and clean or replace the

spark plug.

Adjust the spark plug electrode gap

to 0.024 0.028 inch (0.6-0.7 mm). If

the spark plug must be replaced, use

only an Champion CJ8Y or NGK

BPMR7A, or equivalent resistor type

spark plug of the correct heat range.

CAUTION!

Before removing the spark plug,

clean the area around the plug to

prevent dirt and debris from getting

into the engine’s internal parts.

Clean the spark plug

and check the gap at

the electrode.

10/15-Hour Maintenance

0.024–0.028 inch

(0.6–0.7 mm)

Maintenance (continued)

(more frequently in dusty or dirty

conditions)

Remove and clean the cylinder cover

and clean grass and dirt from the cyl-

inder fins.

Remove and replace the fuel filter

element.

Use a hooked wire to remove the

fuel filter element.
Before reinstalling the new filter

element, inspect the condition of all

the fuel system components (fuel

pick-up line, fuel return line, tank

vent line, tank vent, fuel cap and fuel

tank).
If damage, splitting or deterioration

is noted, the unit should be

removed from service until it

can be inspected or repaired

by a Shindaiwa-trained service

technician.

Filter

Element

Hooked Wire

50 hour maintenance

CAUTION!
Make sure you do not pierce the

fuel line with the end of the hooked

wire, the line is delicate and can be

damaged easily.