Select, Residential gas water heaters – State Industries 201 Series User Manual
Page 2
For complete information on limited warranties, consult written warranty,
or contact the State Customer Care Center, 1-800-365-0024.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
Recoveries are rounded to nearest gallon.
For 10-Year Tank and 6-Year Parts Warranty, change "6" to "X" in Model Number (GSX 40 YBRT).
Water Connections – 3/4" male on all models.
When ordering Propane, change "Y" to "H" in model number (GS6 40 HBRT).
External heat trap nipples are factory-installed on all models.
† Propane Gas – 40,000 for 50-gallon short, 37,000 for the 50-gallon tall,
36,000 input for 40-gallon models and 32,000 for 30-gallon models.
SELECT
®
Residential Gas Water Heaters
For more information on Select
®
contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024 Toll-free USA
www.statewaterheaters.com
SRGSS02408
R E S I D E N T I A L
State FVIR design meets the American National Standards Institute standards (ANSI Z21.10.1 - CSA 4.1) that deal with
the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
Feature a sealed combustion chamber with air intake filter and a flame arrestor built into the water heater base. In addition, a thermal
cutoff (TCO) device, is designed to shut off gas flow to the burner and pilot if
poor combustion is detected.
Flammable Vapor Ignition Resistant (FVIR) Water Heaters
If flammable vapors accidentally enter the
combustion chamber, the arrestor is designed
so flames burn off the top surface and can not
escape down through the arrestor.
A. Industry standard thermopile
B. Large View Port for easy burner inspection
C. 360
0
combustion air filter
D. Thermal Cutoff (TCO) with manual reset
Maximum Hydrostatic Working Pressure: 150 PSI.
When ordering top-mounted T&P Valve, add "G" to model number (GS6 40 YBRT G).
Propane (LP) models are Series 201
BTU INPUT RECOVERY
DRAFT
SHIPPING
PER HOUR 90°F RISE
A B C D E F
HOOD
WEIGHT
NATURAL† GALLONS
OUTLET
(LBS)
DIMENSIONS IN INCHES
58-1/4
18
13
51-3/4
138
TALL MODELS
SHORT MODELS
1
PEAK
DEMAND
OUTPUT
(1st Hour
Rating
Gallons)
APPROX
ENERGY
FACTOR
GALLON
CAPACITY
FOAM
THICK-
NESS
(Inches)
MODEL
NUMBER
20
13
8
50-1/4
3 or 4
153
60-3/4
1
41
40,000
50
.58
88
GS6 50 YBRT
57
41
61-3/4
Revised April 2013
50
1
36
35,500
30
.61
60
GS6 30 YORS
GS6 30 YORT
18
13-1/2
8
46-3/8
40
3 or 4
113
61-1/2
1
36
35,500
30
.61
67
16
13
8
58
52
3 or 4
112
51-1/2
1
41
40,000
40
.59
66
GS6 40 YBRS
20
13
8
47-3/4
41
3 or 4
135
Low Lead Content
300/301 Series
B
A
F
D
1/2" GAS
CONNECTION
VALVE
C
COLD
CONNECTION
E
HOT
CONNECTION
ANODE ROD
(OPTIONAL T&P
LOCATION)
GS6 50 YBRS
93
.61
50
40,000
41
2
53-1/4
49-1/2
24
13-1/4
8
42-1/2
3 or 4
175
255867_SRGSS02408.indd 2
255867_SRGSS02408.indd 2
4/10/13 11:49 AM
4/10/13 11:49 AM