Flow Chart of Troubleshooting

10-22

This Document can not be used without Samsung's authorization

10-2-4. DCS TX

CONTINUOUS TX ON CONDITION

CH : 698CH(DCS)

TX POWER CODE: 520 CODE Aplied

RBW : 100KHz

VBW : 100KHz

SPAN : 10MHz

REF LEV. : 10dBm

ATT. : 20dB

PAM100

pin

12

: about 2~3

dBm?

C199,RFS100

check&change

PAM100

pin6 : 2.8 V?

U107

check & change

PAM100

pin7 : 3.7 V?

NO

NO

YES

YES

NO

BATTERY

check & change

PAM100

pin 8 : 1.6V ?

YES

NO

PAM100 pin1

about : -5dBm

?

YES

PAM100

pin 4 : 0V?

YES

YES

PAM100

change or resolder

NO

U107

check

R118

Check

NO

U102

pin12,13,25,26,

28 : 2.8V ?

U107

pinA13

,C172

change or resolder

YES

U102

pin30,31 :

26MHz ?

Vp-p : 950mV?

U102

pin4,5,6,7:100m

V?

YES

U107

change or resolder

NO

NO

YES

NO

OSC100

change or resolder