Model W1781 21˚ Framing Nailer

-15-

Troubleshooting

Symptom

Possible Cause

Cause

Possible Solution

Air leaking at trig-

ger valve area.

1. O-rings in trigger valve

housing are damaged.

1. O-rings must be replaced

& operation of safety nose

must be checked.

Air leaking

between housing

and hose

1. Loose screws in housing.

2. Damaged O-ring.

3. Loose air fitting.

1. Reseal and tighten screws.

2. Replace O-ring.

3. Tighten air fitting & use

teflon tape.

Air leaking

between housing

and cap.

1. Damaged seal.

1. Replace damaged seals.

Tool skips nails

while discharging.

1. Excessive air pressure.

2. Air leaks.

3. Dirt in nose.

4. Dirt or damage prevents nails

from moving freely.

5. Inadequate air flow to tool.

6. Worn piston O-ring or lack of

lubrication.

7. Damaged trigger valve O-

rings.

8. Worn bumper.

9. Cap seal leaking.

1. Reduce air pressure to

tool.

2. Reseal and tighten screws

and fittings.

3. Clean nose.

4. Clean magazine and

inspect/repair damage.

5. Check fittings, hose,

compressor, and air

pressure.

6. Replace O-ring and

lubricate.

7. Replace trigger valve O-

rings.

8. Replace bumper.

9. Replace cap seal.

Tool runs slowly

or has a loss of

power.

1. Undersized air hose.

2. Nailer is not lubricated.

3. Broken spring in cap

assembly.

4. Exhaust port in cap is

blocked.

1. Use a larger hose.

2. Lubricate nailer.

3. Replace spring.

4. Clean or replace damaged

internal parts.

Fasteners frequent-

ly jam the nailer.

1. Nails are the wrong size.

2. Nails are bent or dirty.

3. Magazine or nose screws are

loose.

4. Driver or driver guide are

worn or damaged.

5. Nails are wrong angle.

1. Use correct nails.

2. Use undamaged, clean

nails.

3. Tighten magazine.

4. Replace worn or damaged

parts.

5. Use correct angle nails.

Nailer does not

fire.

1. Nailer is not lubricated.

2. Nail is jammed in magazine or

discharge area.

3. Piston shaft is damaged.

4. Air pressure too low.

1. Follow lubricating

instructions.

2. Clear nailer magazine or

discharge area.

3. Replace piston shaft.

4. Check/increase air

pressure.