C. Frame the Heater
Figure 3.2 shows a typical framing (using 2 x 4 lumber) of 
the heater, assuming combustible materials are used. All re-
quired clearances to combustibles around the heater must 
be adhered to. 
A
B
(header height)
9-3/4 in.
(248 mm)
NOTE: The height that a combustible mantel is 
fitted above the heater is dependent on the 
height of the front selected. The minimum 
height is 1 in. (25 mm) above the front. Fronts 
are available 24 in. (610 mm), 28 in. (711 mm) 
and 32 in. (813 mm) high for the 26 in. heater 
and 21 in. (533 mm) and 28 in. (711 mm) high 
for the 23 in. heater.
See Section 6.C. for mantel specifications.
Figure 3.2
Framing the Heater
Model #
A
B
CF230E-B
in.
23-1/2
18-1/4
mm
597
464
CF260E-B
in.
26-1/2
22-7/8
mm
673