SPECIFICATION

Model no.

WA-1400E
WA-1410E

WA-1400H
WA-1410H

Cooling capacity

14000 BTU/hr

14000 BTU/hr

Heating capacity

-

14000 BTU/hr

Power/Ampere
consumption for cooling*

1250W/ 11.0A

1250W/ 11.0A

Power/Ampere
consumption for heating*

-

1250W/ 11.0A

Air volume (max. speed)

580m

3

/h 580m

3

/h

Humidity removal capacity

53.9 L/day

53.9 L/day

Recommended room size

500sq.ft.

500sq.ft.

Power supply

115V/60Hz/1phase

Compressor Rotary
Refrigerant

R-22

Refrigerant load*

680 g

Fan speed

3

Timer

1~ 24 hours

Working temperature

Cooling: 64.4

o

F~ 110

o

F

Heating: 41

o

F~ 80.6

o

F

Thermostat

62

o

F ~ 90

o

F

Exhaust pipe

5 in x 59 in

Net Weight

86 lbs.

Dimension

14 x 21 x 30 in (WxDxH)

REMARK:

1. The data marked with '*' may vary for technical reasons.
2. Measuring condition for above is: Cooling – RT80.6

o

F, RH60%

Heating – RT68

o

F, RH60%

*RT means room temperature
*RH means room humidity.

Un-insulated rooms such as sunrooms, garages, or attics should be less
than 500sq.ft.

The following may effect the unit in reaching your set tempearature:
Outside Temperature, Room Size, Ceiling Height, Room Insulation,
Number of people in the room, Direct Sunlight and Source of Heat.