Soleus Air PH3-10R-03 User Manual
Page 13
13
Compressor Indicator
The “
” icon will light up on the control panel display when the compressor turns on. The “
” icon will
turn off when the compressor shuts off.
Emergency Condensate Holding Tank
When the unit is in cooling mode, unwanted water is extracted from the air. Most of this water is used to cool the unit
and make it run more efficiently. When the unit is used in extremely humid environments, water will collect in a water
container at the bottom of the unit. When the water container is full, the compressor will stop but the fan will continue to
run.
When the water container is full, the unit will display ‘
’ on the control panel until the tank is emptied. To resume
operation, empty the water container according to the following steps:
1.
Turn the unit off. Do not move the unit when the water container is full.
2.
Place the drain pan accessory under the drainage port at the back of the unit.
3.
Remove the rubber plug from the drain hole. The condensate water will drain out automatically. When the drain pan
is full, replace the rubber plug into the drainage hole to stop the water flow. Empty the drain pan. Repeat until all the
water is emptied.
Once the water container has been emptied, replace the rubber plug into the drain hole firmly. Do not
allow the water to drip continuously into the drain pan, as it might easily overflow.