beautypg.com

Skylink WE-001 User Manual

Wall switch

background image

2. SETUP

respectively to the existing wires from the wall :

Secure the Wall Switch with the provided screws.

The two blue LEDs will be on.

Note: If the 2 blue LEDs remain off, please check and ensure the light
bulb is installed and in good condition.

status of the load connected

Setup of the Wall Switch is simple. Simply replace your existing wall switch
by the Wall Switch.

CAUTION
Installation is required and enclosed instructions must be followed
carefully to all steps and notes. If you are uncertain or uncomfortable
performing this installation, please consult a qualified electrician.
This manual should also be retained for future reference.

1. Turn off power to the circuit that you plan on installing the Wall Switch
to at the circuit breaker.

WARNING
Failure to turn off power at the circuit breaker can result in electrical
shock causing severe or fatal injury.

Note:
The Wall Switch is designed to operate maximum load of 1000W at
120VAC.

2. Follow the diagrams below to install the Wall Switch with the 2 wires:
Live, Load. Use the provided wire nuts to connect these wires

3. After all the wires are connected, ensure that all of the wire connectors
are attached securely and there should be no exposed copper wiring.

4. Turn the circuit breaker back on.

5. The

will be off. The Wall Switch is now

installed and you can begin programming to learn transmitters into the
Wall Switch.

Load (red) to load and

Live (Black) to live. Ground (Green) to Ground.

3. PROGRAMMING TRANSMITTERS SENSORS

There are 2 operating modes with the

:

1) On/Off Mode - When a valid signal is received, it will turn on or off the
load

2) Countdown Timer Mode - When a valid signal is received, the load will
be on for a specific period of time, 1 minute, 5 minutes, 15 minutes,
30 minutes, or 60 minutes. This is mainly for energy saving.

Wall Switch

In order to operate the

remotely with a transmitter or sensor, it

must be programmed to the

. Each module can be operated

by up to 8 different transmitters (or 8 different command signals).

Wall Switch

Wall Switch

You can program multiple transmitters / sensors to the module and
different transmitter / sensor can activate a different mode.

Push the switch

button on the Wall Switch.

To program a transmitter into the Wall Switch, follow the instructions
below:

Before you program a transmitter to the Wall Switch, decide the operating
mode for this transmitter (On/Off Mode, or Countdown Timer Mode).

1. Wall Switch must be installed and powered properly.

The connected load should be on, and the

2 blue LEDs are off.

2. Press and hold the "SET" button for about 3 seconds, the upper blue
LED flashes quickly, meaning it is in On/Off Mode programming sequence.
Release the "SET" button if you are programming a transmitter to operate
in On/Off Mode.

3. If you are programming a transmitter to operate in Countdown Timer
Mode, continue to hold the "SET" button for about 10 seconds, until the
upper blue LED is on steadily on, then release the "SET" button.

4. Transmit a "Learn" code from the transmitter. Refer to the manual of the
transmitter to transmit this "Learn" code.

5. Once the transmitter is programmed, the both blue LEDs flash quickly
then stops flashing. You have successfully programmed the transmitter.

Operating Mode

On / Off

Countdown Timer

Upper LED Indication

Flashes quickly

Steadily On

Note: You must complete the programming sequence within the
15-second interval, otherwise, the Wall Switch will quit from programming
mode and you need to start again from step 1 if the blue LED is off.

1. INTRODUCTION

Wall Switch
WE-001

Model WE-001

Wall Switch

Wire nuts

TM

Thank you for your purchase of a SkylinkHome receiver, Wall Switch,
Model WE-001. Simply replace your existing wall switch with this Wall
Switch, you can then wirelessly turn on and off

TM

with a SkylinkHome transmitter.

The Wall Switch WE-001 can communicate with up to 8 transmitters, so
user has the option to add more transmitters to the system, such as more
remote controls, or motion sensors etc.

All wireless signal communications within the

System are

based on rolling code technology to ensure highest security is used.

The following items are included in this package:

- Wall Switch
- Wire nuts
-

lights or appliances,

etc

TM

SkylinkHome

User’s Instructions

Red

Load

Green

Ground (Usually copper

or green)

Grey Antenna

Do not cut the antenna!

Black

Live

SET
Button

Switch Button

Blue
LEDs

4. SET TIMER DURATION

This section is for transmitters that are programmed for Countdown Timer
Mode.

The timer for Countdown Timer Mode can be set to the following duration,
meaning the light will stay on for the following time: 1 minute, 5 minutes,
15 minutes, 30 minutes, or 60 minutes. Only one timer interval can be set.
To set the timer duration, follow the instructions below.

Note:
Antenna
( grey wire) -- Do not cut it, keep it as straight as possible.
Put the antenna directly into the dry wall or through a hole of the
metal box into the dry wall to get more control distance with a remote.

1. Wall Switch must be installed and powered properly. The connected
load should be off, and the 2 blue LEDs are on. The load must be off in
order to set the timer duration.

2. Press and hold the SET button for 3 seconds, the lower blue LED
flashes once. The number of flashes indicates the timer duration:

Number of Flashes

1

2

3

4

5

Timer Duration

1 min.

5 min.

15 min.

30 min.

60 min.

3. Continue to hold the SET button until it reaches the desired setting. The
status will change every 6 seconds, i.e. hold the SET button for another
6 seconds, you will see the number of flashes changes from 1 to 2, 2 to
3, etc.

Table of contents