Planning Information

Model W362418 (R) Pro Wall Hood

6

Dimensions in parentheses are in
millimeters unless otherwise specified.

Ducting considerations for
Pro 24" (610) deep wall
hoods.

DUCTWORK INSTALLATION

THROUGH ROOF

24"

(610)

DEPTH OF HOOD

ROOF CAP OR REMOTE BLOWER

10" ROUND DUCT

SOFIT OR CABINET

OR DUCT COVER

WALL CAP

OR REMOTE BLOWER

*HORIZONTAL DISCHARGE IS APPLICABLE ON 24" (610) DEEP WALL HOODS

USED WITH WBLOWER-60INT, WBLOWER-120INT OR ANY WOLF REMOTE BLOWER.

WBLOWER-90INT IS NOT FOR USE IN HORIZONTAL DISCHARGE APPLICATIONS.

DUCTWORK INSTALLATION

THROUGH WALL

DISCHARGE COLLAR

HORIZONTAL

DISCHARGE*

VERTICAL DISCHARGE

TRANSITION

22

1

/

4

"W x 9"D TO 10" ROUND

10"H (INCLUDING FLANGES)

30"

TO

36"

(762–914)

COUNTERTOP

TO BOTTOM OF

VENTILATION HOOD

36"

(914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

18"

(457)

HEIGHT OF HOOD

WALL HOOD

D U C T I N G C O N S I D E R A T I O N S

Wolf Pro 24" (610) deep wall hoods are shipped

without the blower assembly. Internal, in-line or

remote blower assemblies are available. The

remote blower can be mounted on the roof or an

exterior wall. Refer to the illustration below for

ducting options.

Pro 24" (610) deep wall hoods have an adjust-

able discharge location that can run vertically or

horizontally. Horizontal discharge is applicable

on 24" (610) deep hoods used with WBLOWER-

60INT or WBLOWER-120INT or any remote

blower. WBLOWER-90INT is not for use in hori-

zontal discharge applications.

Refer to the Pro ventilation charts at the end of

this section for recommendations and blower

options

.