beautypg.com

Coin slide-op control panel netmaster, Control panel, Micro-display control panel (mdc) – Speed Queen AM07-500 User Manual

Page 2

background image

T

o p l o a d

W

a s h e r

Coin Slide-Op Control Panel

NetMaster

®

Control Panel

Features:

User selectable options for hot, warm or cold wash

temperatures. Two speeds with normal/gentle wash and slow/fast
extract. Six total cycles with three “water saver” cycles and three
regular selections with LEDs. MEF of 1.26 and Water Factor of 9.5.

Micro-DISPLAY Control Panel (MDC)

Features:

Vacuum Fluorescent Display for vend price and cycle

time countdown. Touch Pad Control with LEDs. Three Temperature
Selections
for hot, warm or cold water. Three Fabric Selections for
Normal, Permanent Press or Delicate. Regular 12 lb extra-large
capacity with 3 lb small load option. Push-to-Start activation.
MEF of 1.34 and Water Factor of 9.4.

Features:

LED Digital Display for vend price and cycle time countdown.

Touch Pad Control with LED. Four Fabric Cycle Selections for
Normal/Hot, Normal/Warm, Permanent Press/Warm, Delicate/Cold.
Push-to-Start activation. MEF of 1.50 and Water Factor of 8.8.

WATER MANAGER ADVANTAGES

NETMASTER CYCLE DEFAULT AND PROGRAMMING

Feature

Default Setting

Options

Wash Time

10 Minutes

0–15 Minutes

Deep Rinse

4 Minutes

0–15 Minutes

Spin

6 Minutes

0–15 Minutes

Vend Price

$1.00

$0.25 - $655

Fabric Selector

Perm Press

Normal or Delicate

Temp Selector

Warm

Hot or Cold

Two-Speed Cycle Operation

Wash/Rinse

Spin/Extract

Cycle

Action

First Rinse

Final Spin

Normal

Normal

High

High

Perm Press**

Normal

Low

High

Delicate

Gentle

Low

High

Two-speed wash and spin cycles. **Standard setting.

NetMaster and MDC models are available with card or coin start operation.

World’s Leading Supplier of Commercial Laundry Equipment

www.speedqueen.com

AM07-500

• High efficiency automatic washers are U.S. DOE

compliant to 2007 commercial washer standards
for energy and water.

• Special multi-housing cycle for superior washability

– Extended wash, rinse and spin times
– Reduced spray rinse to save water

• Low average hot water usage per cycle

– Cold water rinses (factory set)

NetMaster Topload DOE “J1” Testing

Water

Total Water

DOE

Temp

Hot

Cold

Consumption Cycle %

Hot

14.0

15.7

29.7 Gal

14%

Warm

5.4

24.3

29.7 Gal

49%

Cold 0.0

29.7

29.7

Gal

37%

Average Hot Water Per Cycle

4.61 Gal

* Water usages may vary for your particular application.

Coin Slide Topload DOE “J1” Testing

Water

Total Water

DOE

Temp

Hot

Cold

Consumption Cycle %

Hot

15.1

11.0

26.1 Gal

14%

Warm

4.8

21.3

26.1 Gal

49%

Cold 0.0

26.1

26.1

Gal

37%

Average Hot Water Per Cycle

4.48 Gal

* Water usages may vary for your particular application.

MDC Topload DOE “J1” Testing

Water

Total Water

DOE

Temp

Hot

Cold

Consumption Cycle %

Hot

9.1

14.6

23.7 Gal

14%

Warm

3.5

20.2

23.7 Gal

49%

Cold 0.0

23.7

23.7

Gal

37%

Average Hot Water Per Cycle

2.99 Gal

* Water usages may vary for your particular application.

Operational Efficiencies

FEATURES AND OPERATION