beautypg.com

How to replace the belt and/or agitator assembly, How to replace the belt agitator assembly – Sharp EC-S5170 User Manual

Page 17

background image

17

When replacing the belt, always set the RUG/FLOOR Selector pedal in the "FLOOR"
position.

1

2

3

4

5

Fig.41

HOW TO REPLACE THE BELT AGITATOR ASSEMBLY

After removing the bottom plate (see page 13)
to determine if the belt or the agitator is worn or
broken.

Be sure that the flat belt is not twisted and all
rotating parts move smoothly. (Fig.43)
And secure the bottom plate with four screws.
(see page 13)

Pull out the agitator and then remove the flat
belt from the motor shaft. (Fig. 42)

Loop the (new) belt around the motor shaft and
(new) agitator as shown. (Fig. 42)

Then re-insert the (new) agitator assembly,
making sure that both ends of the agitator
assembly fit in the groove of the nozzle head.
(Fig. 43) Be sure to install the new flat belt into
the belt guide properly. (Fig. 43)

Fig.43

Idler Pulley

Flat Belt

(To insert the agitator assembly into
the nozzle head, follow the Arrow
direction as indicated.)

Belt Guide

Motor Shaft

Agitator Assembly

Flat Belt

Main Pulley

Arrow

Main Pulley

Idler Pulley

AND

OR

Motor Shaft

Agitator Groove

Fig.42

2001.12.20, 8:07 AM