Sennheiser SKP 3000 User Manual
Page 28
60
Nominal input sensitivity
(at nominal deviation and 1 kHz)
0 dB,
22 mV
–10 dB,
70 mV
–20 dB, 220 mV
–30 dB, 700 mV
–40 dB,
2,0 V
–50 dB,
2,0 V
(limited by a protective circuit)
Max. input voltage
(at peak deviation)
2.8 V
rms
THD (at nom. deviation and 1 kHz)
≤
0,3 %
Overall unit
Power supply
2 AA size batteries, 1.5 V
or BA 2015 accupack
Microphone phantom powering
48 V
±
4 V (at 2 mA)
Max. power consumption:
!
at nominal voltage (2.4 V)
!
with switched-on
phantom powering
!
with switched-off
transmitter
approx. 190 mA
approx. 280 mA
≤
250 µA
Operating time:
!
with switched-off phantom
powering
!
with switched-on phantom
powering
Battery
BA 2015
>
8 h
>
8 h
>
5 h
>
5 h
Temperature range
–10 °C to +55 °C
Dimensions [mm]
105 x 43 x 43
Weight (incl. batteries)
approx. 195 g