Perating, Nstructions, D-drive – Stanley Black & Decker 2005 Series User Manual
Page 6: Multi-user electronic safe lock
➥
c
reatIng
the
t
Ime
d
eLay
o
verrIde
c
ode
The TDO code is located in position 9. It is programmed as follows.
7 4 ✽
master code or supervisor code
#
♪♪♪♪♪
9
(position number)
#
♪♪♪
new TDO code
#
♪♪♪
new TDO code
#
♪♪♪
➥
c
hangIng
the
t
Ime
d
eLay
o
verrIde
c
ode
An existing TDO code can only be changed by the holder of that code,
as follows.
2 2 ✽ OLD TDO CODE #
♪♪♪♪♪
NEW TDO CODE #
♪♪♪
NEW TDO CODE #
♪♪♪
➥
d
eLetIng
the
t
Ime
d
eLay
o
verrIde
c
ode
The TDO code is deleted as follows.
7 4 ✽
master code or supervisor code
#
♪♪♪♪♪
9
(position number)
#
♪♪♪
#
♪♪♪
#
♪♪♪
m
anagement
/e
mpLoyee
a
ccess
m
ode
➥
t
ypes
of
m
anagement
/e
mpLoyee
a
ccess
Management/employee access is an alternate way to operate this lock,
to meet special security needs. Your lock can be programmed so that
during everyday operation, the
master code holder or supervisor
code holder can enable the lock. It can then be opened using any valid
lock code (
master, supervisor, or user code), until it is disabled.
There are two varieties of the enable/disable function.
In the first version, only the holder of the
master code and
supervisor code can enable and disable the lock.
In the second version,
user code holders can also disable the lock.
The
master code and supervisor code holders are the only persons
who can both enable and disable the lock.
➥
p
rogrammIng
the
L
ock
for
m
anagement
/e
mpLoyee
a
ccess
m
ode
Your lock can be programmed so that the
master code holder or
supervisor code holder can use his code to enable the lock for
opening by any valid lock code. When either the
master code or
supervisor code is again to toggle the lock, it can no longer be
opened. This process can be repeated whenever appropriate.
3 2 ✽
master code
#
♪♪♪♪♪
2
#
♪♪♪
2
#
♪♪♪
After this programming procedure is completed, the lock will be
disabled. If a valid code is entered, the lock will emit a double
beep, but will not open.
➥
e
nabLIng
the
L
ock
In
m
anagement
/e
mpLoyee
a
ccess
m
ode
Before valid codes can be entered to open the lock, it will be
necessary to perform the following procedure.
5 5 ✽
master code or supervisor code
#
♪♪♪♪
Note that the lock emits four beeps to indicate that it can now
be opened by any valid code.
➥
d
IsabLIng
the
L
ock
In
m
anagement
/e
mpLoyee
a
ccess
m
ode
To make the lock inoperable by any code, simply repeat the same
programming procedure.
5 5 ✽
master code or supervisor code
#
♪♪
Note that the lock emits two beeps to indicate that it is now
disabled, and cannot be opened by any code.
This sequence simply toggles the lock on and off to determine
whether or not it can be opened by the
master code, supervisor
code, or any user code. When the lock is disabled, it will emit a
double beep when a code is entered, but will not open.
➥
L
ettIng
u
sers
d
IsabLe
the
L
ock
In
m
anagement
/e
mpLoyee
a
ccess
m
ode
Only the holder of the
master code or supervisor code can enable
the lock, but there may be circumstances under which you want
user code holders to also be able to disable the lock. To allow
this, perform the following procedure.
5 6 ✽
master code
#
♪♪♪♪♪
1
#
♪♪♪
1
#
♪♪♪
Now, after the lock is enabled by the
master code or supervisor
code holder, any user code holder can disable it by entering the
following sequence.
5 5 ✽
any user code
#
♪♪
When the lock is disabled, it will emit a double beep when a
code is entered, but will not open.
© Copyright 2006, Sargent & Greenleaf
Page 6
O
perating
i
nstructiOns
S&G
®
Z
03
D-Drive
™
Multi-User Electronic Safe Lock
2005 Series